Max Voltage<br />

Drop<br />

3.5 Volts<br />

3.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

3 Volts<br />

Enclosure<br />

Classification Temperature Rating Lead Wire Length Plug-In Cable<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 8 mm Plug-in<br />

Magnetically operated switches (cont)<br />

CS8-2-* and CS7-* Switches (tie rod mounting bracket included)<br />

CS8-PIC-2 (2m)<br />

CS8-PIC-5 (5m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 8mm plug-in<br />

CS8-PIC-2 (2m)<br />

CS8-PIC-5 (5m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 8mm plug-in<br />

CS8-PIC-2 (2m)<br />

CS8-PIC-5 (5m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

Wiring Diagrams<br />

Hard Wired<br />

WHT<br />

_<br />

Supply<br />

120V Max BRN<br />

+<br />

0.45<br />

Load<br />

Center of Sensing area<br />

+ BRN<br />

Supply WHT<br />

6-24 VDC GRN<br />

_<br />

0.10<br />

Load<br />

Center of Sensing area<br />

WHT<br />

_<br />

BRN<br />

Supply<br />

6-24 VDC GRN<br />

+<br />

0.10<br />

Load<br />

Center of Sensing Area<br />

ACTUATORS<br />

3 Volts<br />

3 Volts<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 12 mm plug-in<br />

CS7-PIC-5 (5m)<br />

CS7-PIC-10 (10m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

+<br />

Supply<br />

AC/DC<br />

_<br />

Load<br />

BLK<br />

RED<br />

3 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

.5 Volts<br />

N/A<br />

N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 12mm plug-in<br />

CS7-PIC-5 (5m)<br />

CS7-PIC-10 (10m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 12mm plug-in<br />

CS7-PIC-5 (5m)<br />

CS7-PIC-10 (10m)<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

NEMA 6 & CSA<br />

Approved -22 F to + 176 F 9 Feet N/A<br />

RED<br />

+<br />

Supply<br />

6-24 VDC<br />

_<br />

AC<br />

supply<br />

BLK<br />

_<br />

Supply<br />

AC/DC<br />

+<br />

BLK<br />

Load<br />

BLK<br />

WHT<br />

Load<br />

RED<br />

WHT<br />

Load<br />

WHT<br />

RED<br />

SWITCH<br />

RED<br />

+ ~<br />

–<br />

HOT<br />

BLK<br />

- ~<br />

–<br />

NEUTRAL<br />

N/A<br />

NEMA 1,4, and 13<br />

(General Location) -4 F to +176 F 9 Feet N/A<br />

Both direct and alternating current<br />

Earth (ground) TERMINAL<br />

GRN<br />

GROUND<br />

CS7 Series<br />

1.28<br />

.86<br />

.68<br />

Indicator<br />

light<br />

Hook up<br />

cable<br />

.68<br />

1.66<br />

1.27 .327<br />

.85<br />

1.40<br />

<strong>Norgren</strong>.com/usa – 303.794.2611 – help@amer.norgren.com<br />