FLUE OUTLET<br />
16<br />
Notes.<br />
1. It is recommended that a support bracket<br />
is fitted for every 1 metre of extension pipe<br />
used and a bracket should be used at every<br />
joint, to ensure pipes are held at the correct<br />
angle.<br />
2. When extension ‘D’ packs are used the flue<br />
duct MUST be inclined at 1.5 degrees to<br />
the horizontal to allow condensate to drain<br />
back into the boiler and out through the<br />
condensate drain.<br />
3. If the B pack, or telescopic B pack only are<br />
used, they may be mounted horizontally.<br />
The 1.5 degrees is taken care of by the<br />
inclination of the flue within the air pipe.<br />
4. Only use water as a lubricant during<br />
assembly.<br />
INsTaLLaTION<br />
9 DETERMININg ThE FLUE LENgTh aND FLUE paCKs REqUIRED CONT’D<br />
10 FLUE assEMBLy - Exploded View<br />
An optional flue duct extension<br />
kit is required for wall<br />
thicknesses greater than :<br />
side 378mm<br />
Rear 420mm<br />
LEgEND<br />
1. Duct assembly.<br />
2. Flue turret.<br />
3. Turret clamp.<br />
3<br />
Telescopic B Pack shown<br />
NON - TELEsCOpIC FLUE<br />
Total Flue length dimension Flue<br />
(measuring from CL of turret to outside wall)<br />
Rear flue Side flue Extra packs Boiler<br />
dim. x+155 dim. L+197 required size<br />
Up to 640 mm Up to 640 mm none <strong>24</strong>,<strong>30</strong><br />
Up to 1590 mm Up to 1590 mm Pack D - 1 off <strong>24</strong>,<strong>30</strong><br />
Up to 2540 mm Up to 2540 mm Pack D - 2 off <strong>24</strong>,<strong>30</strong><br />
Up to 3490 mm Up to 3490 mm Pack D - 3 off <strong>24</strong>, <strong>30</strong><br />
Up to 4440 mm Up to 4440 mm Pack D - 4 off <strong>24</strong>, <strong>30</strong><br />
Up to 5390 mm Up to 5390 mm Pack D - 5 off <strong>24</strong>, <strong>30</strong><br />
Up to 6340 mm Up to 6340 mm Pack D - 6 off <strong>24</strong>, <strong>30</strong><br />
Up to 7290 mm Up to 7290 mm Pack D - 7off <strong>24</strong> & <strong>30</strong><br />
Up to 8<strong>24</strong>0 mm Up to 8<strong>24</strong>0 mm Pack D - 8 off <strong>24</strong> & <strong>30</strong>*<br />
Up to 9000 mm Up to 9000 mm Pack D - 9 off <strong>24</strong><br />
* i-mini <strong>30</strong> is capable of 8m flue only<br />
TELEsCOpIC FLUE<br />
Total Flue length dimension Flue<br />
(measuring from CL of turret to outside wall)<br />
Rear flue Side flue Extra packs Boiler<br />
dim. x+155 dim. L+197 required size<br />
Up to 575 mm Up to 575 mm none <strong>24</strong>,<strong>30</strong><br />
Up to 1525 mm Up to 1525 mm Pack D - 1 off <strong>24</strong>,<strong>30</strong><br />
Up to <strong>24</strong>75 mm Up to <strong>24</strong>75 mm Pack D - 2 off <strong>24</strong>,<strong>30</strong><br />
Up to 3425 mm Up to 3425 mm Pack D - 3 off <strong>24</strong>, <strong>30</strong><br />
Up to 4375 mm Up to 4375 mm Pack D - 4 off <strong>24</strong>, <strong>30</strong><br />
Up to 5325 mm Up to 5325 mm Pack D - 5 off <strong>24</strong>, <strong>30</strong><br />
Up to 6275 mm Up to 6275 mm Pack D - 6 off <strong>24</strong>, <strong>30</strong><br />
Up to 7225 mm Up to 7225 mm Pack D - 7off <strong>24</strong> & <strong>30</strong><br />
Up to 8175 mm Up to 8175 mm Pack D - 8 off <strong>24</strong> & <strong>30</strong>*<br />
Up to 9000 mm Up to 9000 mm Pack D - 9 off <strong>24</strong><br />
* i-mini <strong>30</strong> is capable of 8m flue only<br />
2<br />
3G9499a<br />
1<br />
TOP<br />
The flue terminal MUST<br />
be fitted with the ‘TOP’<br />
uppermost to allow the<br />
correct fit and use of<br />
the plume management<br />
system.<br />
i-mini - Installation and Servicing