INsTaLLaTION<br />
33 COMMIssIONINg aND TEsTINg<br />
<strong>30</strong><br />
a. Electrical Installation<br />
1. Checks to ensure electrical safety should be carried out by a<br />
competent person.<br />
2. ALWAYS carry out the preliminary electrical system checks,<br />
i.e. earth continuity, polarity, resistance to earth and short<br />
circuit, using a suitable test meter.<br />
INsTaLLaTION<br />
B. gas Installation<br />
1. The whole of the gas installation, including the meter,<br />
should be inspected and tested for tightness and purged in<br />
accordance with the recommendations of BS. 6891.<br />
In IE refer to IS.813:2002.<br />
2. Purge air from the gas installation by the approved methods<br />
only.<br />
Warning. Whilst effecting the required gas tightness test and purging air from the gas installation,<br />
open all windows and doors, extinguish naked lights and Do noT sMoKe.<br />
gENERaL<br />
please note: The combustion for this appliance has<br />
been checked, adjusted and preset at the factory for<br />
operation on the gas type defined on the appliance<br />
data plate. No measurement of the combustion is<br />
necessary. DO NOT adjust the air/gas ratio valve.<br />
Having checked:<br />
- That the boiler has been installed in accordance<br />
with these instructions.<br />
- The integrity of the flue system and the flue seals,<br />
as described in the Flue Installation section.<br />
Proceed to put the boiler into operation as follows:<br />
ChECK ThE OpERaTIONaL (WORKINg) gas<br />
INLET pREssURE<br />
CH Flow<br />
Set up the boiler to operate DHW atOutlet maximum rate by<br />
opening hot tap to maximum<br />
flow.<br />
Gas Supply<br />
With the boiler operating in<br />
the maximum rate condition<br />
check that the operational<br />
(working) gas pressure at<br />
the inlet gas pressure Blacktest<br />
point complies with Handle the<br />
requirements - refer to “Gas<br />
Yellow<br />
Supply” on page 8. Handle<br />
Ensure that this inlet pressure<br />
can be obtained with all other Gas Pressure<br />
gas appliances in the property Test Point<br />
working.<br />
DHW Inlet<br />
Blue<br />
Handle<br />
CH Return<br />
3G9927<br />
Black<br />
Handle<br />
Safety<br />
Drain<br />
Valve<br />
aTTENTION !<br />
IT Is a CONDITION OF ThE MaNUFaCTURERs WaRRaNTy ThaT ThE<br />
BENChMaRK COMMIssIONINg ChECKLIsT Is FULLy COMpLETED<br />
aND LEFT WITh ThE appLIaNCE<br />
i-mini - Installation and Servicing