Internet Data Sheet<br />
HY[B/I]18T256[40/80/16]0B[C/F](L)<br />
256-Mbit Double-Data-Rate-Two SDRAM<br />
Parameter Symbol DDR2–400 Unit Notes 1)2)3)4)5)<br />
DQS falling edge hold time from CK (write<br />
cycle)<br />
Min.<br />
Max.<br />
t DSH 0.2 — t CK<br />
6)<br />
DQS falling edge to CK setup time (write cycle) t DSS 0.2 — t CK<br />
Clock half period t HP MIN. (t CL, t CH )<br />
Data-out high-impedance time from CK / CK t HZ — t AC.MAX ps<br />
Address and control input hold time t IH (base) 475 — ps<br />
Address and control input pulse width t IPW 0.6 — t CK<br />
(each input)<br />
Address and control input setup time t IS (base) 350 — ps<br />
DQ low-impedance time from CK / CK t LZ(DQ) 2 × t AC.MIN t AC.MAX ps<br />
DQS low-impedance from CK / CK t LZ(DQS) t AC.MIN t AC.MAX ps<br />
MRS command to ODT update delay t MOD 0 12 ns<br />
11)<br />
12)<br />
10)<br />
10)<br />
13)<br />
13)<br />
Mode register set command cycle time t MRD 2 — t CK<br />
OCD drive mode output delay t OIT 0 12 ns<br />
Data output hold time from DQS t QH t HP –t QHS —<br />
Data hold skew factor t QHS — 450 ps<br />
Average periodic refresh Interval t REFI — 7.8 μs<br />
Average periodic refresh Interval t REFI — 3.9 μs<br />
Auto-Refresh to Active/Auto-Refresh t RFC 75 — ns<br />
16)<br />
command period<br />
Precharge-All (4 banks) command period t RP t RP — ns<br />
Read preamble t RPRE 0.9 1.1 t CK<br />
13)<br />
Read postamble t RPST 0.40 0.60 t CK<br />
13)<br />
Active bank A to Active bank B command t RRD 7.5 — ns<br />
13)17)<br />
period<br />
Active bank A to Active bank B command t RRD 10 — ns<br />
15)21)<br />
period<br />
Internal Read to Precharge command delay t RTP 7.5 — ns<br />
Write preamble t WPRE 0.25 — t CK<br />
Write postamble t WPST 0.40 0.60 t CK<br />
18)<br />
Write recovery time for write without Auto- t WR 15 — ns<br />
Precharge<br />
Internal Write to Read command delay t WTR 10 — ns<br />
19)<br />
Exit power down to any valid command t XARD 2 — t CK<br />
20)<br />
(other than NOP or Deselect)<br />
Exit active power-down mode to Read t XARDS 6 – AL — t CK<br />
20)<br />
command (slow exit, lower power)<br />
Exit precharge power-down to any valid t XP 2 — t CK<br />
command (other than NOP or Deselect)<br />
Exit Self-Refresh to non-Read command t XSNR t RFC +10 — ns<br />
13)14)<br />
15)17)<br />
<strong>Rev</strong>. <strong>1.11</strong>, 2007-07 57<br />
11172006-LBIU-F1TN