c) Pump-Out Timer (S4 dip switch 3 & 4)<br />

CAUTION<br />

Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for this model.<br />

Otherwise, pump motor does not rotate in the pump-out direction.<br />

When a pump-out is called for, the pump motor stops after the preceding freeze cycle.<br />

The pump motor restarts 2 seconds later in the reverse direction, taking water from the<br />

bottom of the tank and forcing pressure against the check valve seat allowing water to<br />

go through the check valve and down the drain. At the same time, water flows through<br />

the small tube to power flush the float switch. The pump motor drains the water tank for<br />

the time determined by the pump‐out timer. The pump‐out timer also acts in place of<br />

the harvest timer during cycles with a pump-out. The pump-out timer is factory set, and<br />

generally no adjustment is required. The pump-out timer control can be set to pump-out<br />

for 10 or 20 seconds.<br />

T1: Time to drain the water tank<br />

T2: Harvest timer at pump-out<br />

S4 Dip Switch Setting Time (seconds)<br />

Inlet<br />

Water<br />

No. 3 No. 4 T1 T2 Valve<br />

OFF OFF 10 150 closed<br />

ON OFF 10 180 closed<br />

OFF ON 10 120 open<br />

ON ON 20 180 closed<br />

d) Pump-Out Frequency Control (S4 dip switch 5 & 6)<br />

The pump-out frequency control is factory set to drain the water tank every 10 cycles,<br />

and generally no adjustment is required. However, where water quality is bad and the<br />

icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The<br />

pump-out frequency control can be set to have a pump-out occur every cycle, or every<br />

2, 5, or 10 cycles.<br />

Timing of the first pump‐out is dependent on S4 dip switch 5 & 6 settings. The first<br />

pump‐out is factory set to occur after the 11th freeze cycle. See the table below.<br />

S4 Dip Switch Setting Pump-Out<br />

No. 5 No. 6 Frequency<br />

1st Pump-Out<br />

OFF OFF Every cycle After 2nd freeze cycle<br />

ON OFF Every 2 cycles After 3rd freeze cycle<br />

OFF ON Every 5 cycles After 6th freeze cycle<br />

ON ON Every 10 cycles After 11th freeze cycle<br />

22