3. Low Ice Production<br />
Low Ice Production - Possible Cause<br />
Long Harvest Cycle<br />
1. Evaporator a) Scaled up.<br />
2. Spray Tubes and/or Spray a) Dirty.<br />
Guides<br />
b) Out of position.<br />
3. Refrigerant Charge a) Low.<br />
4. Water Supply a) Low water pressure.<br />
b) External water filters clogged.<br />
c) Insufficient water line size.<br />
Minimum 3/8" nominal ID (10 mm nominal OD)<br />
d) Too cold.<br />
5. Control Board<br />
a) Thermistor connection loose (K3).<br />
See "IV.B. Control Board Check." b) Defective.<br />
6. Thermistor<br />
a) Loose, disconnected, or defective.<br />
See "IV.E. Thermistor Check."<br />
7. Hot Gas Valve a) Erratic or closed.<br />
8. Inlet Water Valve a) Water valve screen clogged.<br />
9. Compressor a) Inefficient or off.<br />
10. Liquid Line Valve (if applicable) a) Erratic or open.<br />
11. Expansion Valve (TXV) a) Defective.<br />
12. Water Regulating Valve a) Leaking by.<br />
(water-cooled model)<br />
Long Freeze Cycle<br />
1. Evaporator a) Scaled up.<br />
2. Refrigerant Charge a) Low.<br />
3. Air Filter (air-cooled model) a) Clogged.<br />
4. Condenser (air-cooled and a) Clogged.<br />
remote air-cooled models)<br />
5. Condenser (water-cooled model) a) Water temperature out of specification.<br />
6. Control Board<br />
a) Float switch connection loose (K5).<br />
See "IV.B. Control Board Check." b) Defective.<br />
7. Hot Gas Valve a) Erratic or open.<br />
8. Inlet Water Valve a) Leaking by.<br />
9. Float Switch<br />
a) Float does not move freely or defective switch.<br />
See "IV.D. Float Switch Check<br />
and Cleaning."<br />
10. Compressor a) Inefficient or off.<br />
11. Pump Motor a) RPM too slow.<br />
12. Liquid Line Valve (if applicable) a) Erratic or closed.<br />
13. Expansion Valve (TXV) a) Bulb loose.<br />
b) Defective.<br />
14. Headmaster (C.P.R.) (remote a) Not bypassing.<br />
condenser unit)<br />
15. Water Regulating Valve a) Out of adjustment.<br />
(water-cooled model)<br />
See "IV.F. Adjustment of Water<br />
Regulating Valve."<br />
50