3. Low Ice Production<br />

Low Ice Production - Possible Cause<br />

Long Harvest Cycle<br />

1. Evaporator a) Scaled up.<br />

2. Spray Tubes and/or Spray a) Dirty.<br />

Guides<br />

b) Out of position.<br />

3. Refrigerant Charge a) Low.<br />

4. Water Supply a) Low water pressure.<br />

b) External water filters clogged.<br />

c) Insufficient water line size.<br />

Minimum 3/8" nominal ID (10 mm nominal OD)<br />

d) Too cold.<br />

5. Control Board<br />

a) Thermistor connection loose (K3).<br />

See "IV.B. Control Board Check." b) Defective.<br />

6. Thermistor<br />

a) Loose, disconnected, or defective.<br />

See "IV.E. Thermistor Check."<br />

7. Hot Gas Valve a) Erratic or closed.<br />

8. Inlet Water Valve a) Water valve screen clogged.<br />

9. Compressor a) Inefficient or off.<br />

10. Liquid Line Valve (if applicable) a) Erratic or open.<br />

11. Expansion Valve (TXV) a) Defective.<br />

12. Water Regulating Valve a) Leaking by.<br />

(water-cooled model)<br />

Long Freeze Cycle<br />

1. Evaporator a) Scaled up.<br />

2. Refrigerant Charge a) Low.<br />

3. Air Filter (air-cooled model) a) Clogged.<br />

4. Condenser (air-cooled and a) Clogged.<br />

remote air-cooled models)<br />

5. Condenser (water-cooled model) a) Water temperature out of specification.<br />

6. Control Board<br />

a) Float switch connection loose (K5).<br />

See "IV.B. Control Board Check." b) Defective.<br />

7. Hot Gas Valve a) Erratic or open.<br />

8. Inlet Water Valve a) Leaking by.<br />

9. Float Switch<br />

a) Float does not move freely or defective switch.<br />

See "IV.D. Float Switch Check<br />

and Cleaning."<br />

10. Compressor a) Inefficient or off.<br />

11. Pump Motor a) RPM too slow.<br />

12. Liquid Line Valve (if applicable) a) Erratic or closed.<br />

13. Expansion Valve (TXV) a) Bulb loose.<br />

b) Defective.<br />

14. Headmaster (C.P.R.) (remote a) Not bypassing.<br />

condenser unit)<br />

15. Water Regulating Valve a) Out of adjustment.<br />

(water-cooled model)<br />

See "IV.F. Adjustment of Water<br />

Regulating Valve."<br />