Freeze Up - Possible Cause<br />
1. Evaporator a) Scaled up.<br />
b) Damaged.<br />
Freeze Cycle<br />
2. Separators a) Out of position.<br />
3. Spray Tubes and/or Spray<br />
Guides<br />
a) Dirty.<br />
b) Out of position.<br />
4. Refrigerant charge. a) Low.<br />
5. Check Valve a) Defective.<br />
6. Control Board<br />
See "IV.B. Control Board Check."<br />
a) Freeze timer set incorrectly.<br />
b) Defective.<br />
7. Inlet Water Valve a) Leaking by.<br />
8. Float Switch<br />
See "IV.D. Float Switch Check<br />
and Cleaning."<br />
a) Float does not move freely.<br />
b) Defective.<br />
9. Pump Motor a) RPM too slow.<br />
10. Expansion Valve (TXV) a) Defective.<br />
11. Headmaster (C.P.R.) (remote a) Defective.<br />
condenser unit)<br />
12. Water Regulating Valve a) Out of adjustment.<br />
(water‐cooled model)<br />
See "IV.F. Adjustment of Water<br />
Regulating Valve."<br />
49