Freeze Up - Possible Cause<br />

1. Evaporator a) Scaled up.<br />

b) Damaged.<br />

Freeze Cycle<br />

2. Separators a) Out of position.<br />

3. Spray Tubes and/or Spray<br />

Guides<br />

a) Dirty.<br />

b) Out of position.<br />

4. Refrigerant charge. a) Low.<br />

5. Check Valve a) Defective.<br />

6. Control Board<br />

See "IV.B. Control Board Check."<br />

a) Freeze timer set incorrectly.<br />

b) Defective.<br />

7. Inlet Water Valve a) Leaking by.<br />

8. Float Switch<br />

See "IV.D. Float Switch Check<br />

and Cleaning."<br />

a) Float does not move freely.<br />

b) Defective.<br />

9. Pump Motor a) RPM too slow.<br />

10. Expansion Valve (TXV) a) Defective.<br />

11. Headmaster (C.P.R.) (remote a) Defective.<br />

condenser unit)<br />

12. Water Regulating Valve a) Out of adjustment.<br />

(water‐cooled model)<br />

See "IV.F. Adjustment of Water<br />

Regulating Valve."<br />