3. KM-1301SRH-E (remote air-cooled)<br />
APPROXIMATE ICE<br />
AMBIENT TEMP.<br />
WATER TEMP. (ºF/ºC)<br />
PRODUCTION PER 24 HR. (ºF/ºC) 50/10 70/21 90/32<br />
70/21 1270 576 1233 559 1160 526<br />
80/27 1241 563 1183 537 1100 499<br />
90/32 1233 559 1142 518 1062 482<br />
lbs./day kg./day 100/38 1211 549 1123 509 988 448<br />
APPROXIMATE ELECTRIC<br />
CONSUMPTION<br />
70/21<br />
80/27<br />
90/32<br />
1950<br />
1977<br />
1985<br />
1985<br />
2031<br />
2070<br />
2028<br />
2071<br />
2112<br />
watts 100/38<br />
1992<br />
2080<br />
2150<br />
APPROXIMATE WATER<br />
70/21 544 2.06 451 1.71 396 1.50<br />
CONSUMPTION PER 24 HR. 80/27 473 1.79 330 1.25 314 1.19<br />
90/32 451 1.71 228 0.86 194 0.74<br />
gal./day m 3 /day 100/38 342 1.30 220 0.83 163 0.62<br />
FREEZING CYCLE TIME<br />
70/21<br />
80/27<br />
90/32<br />
33<br />
34<br />
34<br />
34<br />
36<br />
37<br />
36<br />
38<br />
40<br />
min.<br />
HARVEST CYCLE TIME<br />
100/38<br />
70/21<br />
80/27<br />
90/32<br />
35<br />
4.7<br />
4.2<br />
4.1<br />
38<br />
4.1<br />
3.3<br />
2.6<br />
42<br />
3.8<br />
3.2<br />
2.4<br />
min. 100/38<br />
3.4<br />
2.6<br />
2.3<br />
HEAD PRESSURE<br />
70/21 210 14.8 225 15.8 238 16.7<br />
80/27 221 15.6 244 17.2 254 17.8<br />
90/32 225 15.8 260 18.3 271 19.1<br />
PSIG kg/cm 2 G 100/38 225 15.8 263 18.5 282 19.8<br />
SUCTION PRESSURE<br />
70/21 50 3.5 51 3.6 55 3.8<br />
80/27 51 3.6 52 3.7 57 4.0<br />
90/32 51 3.6 53 3.7 58 4.1<br />
PSIG kg/cm 2 G 100/38 53 3.7 54 3.8 62 4.4<br />
TOTAL HEAT OF REJECTION FROM CONDENSER<br />
TOTAL HEAT OF REJECTION FROM COMPRESSOR<br />
CONDENSER VOLUME<br />
18,982 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />
2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />
133 CU. IN (URC-14FE)<br />
Note:<br />
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold<br />
should be used for reference only.<br />
2. We reserve the right to make changes in specifications and design without prior<br />
notice.<br />
34