19.01.2015 Views

KM1301SAH-E Service Manual - Hoshizaki

KM1301SAH-E Service Manual - Hoshizaki

KM1301SAH-E Service Manual - Hoshizaki

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3. KM-1301SRH-E (remote air-cooled)<br />

APPROXIMATE ICE<br />

AMBIENT TEMP.<br />

WATER TEMP. (ºF/ºC)<br />

PRODUCTION PER 24 HR. (ºF/ºC) 50/10 70/21 90/32<br />

70/21 1270 576 1233 559 1160 526<br />

80/27 1241 563 1183 537 1100 499<br />

90/32 1233 559 1142 518 1062 482<br />

lbs./day kg./day 100/38 1211 549 1123 509 988 448<br />

APPROXIMATE ELECTRIC<br />

CONSUMPTION<br />

70/21<br />

80/27<br />

90/32<br />

1950<br />

1977<br />

1985<br />

1985<br />

2031<br />

2070<br />

2028<br />

2071<br />

2112<br />

watts 100/38<br />

1992<br />

2080<br />

2150<br />

APPROXIMATE WATER<br />

70/21 544 2.06 451 1.71 396 1.50<br />

CONSUMPTION PER 24 HR. 80/27 473 1.79 330 1.25 314 1.19<br />

90/32 451 1.71 228 0.86 194 0.74<br />

gal./day m 3 /day 100/38 342 1.30 220 0.83 163 0.62<br />

FREEZING CYCLE TIME<br />

70/21<br />

80/27<br />

90/32<br />

33<br />

34<br />

34<br />

34<br />

36<br />

37<br />

36<br />

38<br />

40<br />

min.<br />

HARVEST CYCLE TIME<br />

100/38<br />

70/21<br />

80/27<br />

90/32<br />

35<br />

4.7<br />

4.2<br />

4.1<br />

38<br />

4.1<br />

3.3<br />

2.6<br />

42<br />

3.8<br />

3.2<br />

2.4<br />

min. 100/38<br />

3.4<br />

2.6<br />

2.3<br />

HEAD PRESSURE<br />

70/21 210 14.8 225 15.8 238 16.7<br />

80/27 221 15.6 244 17.2 254 17.8<br />

90/32 225 15.8 260 18.3 271 19.1<br />

PSIG kg/cm 2 G 100/38 225 15.8 263 18.5 282 19.8<br />

SUCTION PRESSURE<br />

70/21 50 3.5 51 3.6 55 3.8<br />

80/27 51 3.6 52 3.7 57 4.0<br />

90/32 51 3.6 53 3.7 58 4.1<br />

PSIG kg/cm 2 G 100/38 53 3.7 54 3.8 62 4.4<br />

TOTAL HEAT OF REJECTION FROM CONDENSER<br />

TOTAL HEAT OF REJECTION FROM COMPRESSOR<br />

CONDENSER VOLUME<br />

18,982 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />

2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />

133 CU. IN (URC-14FE)<br />

Note:<br />

1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold<br />

should be used for reference only.<br />

2. We reserve the right to make changes in specifications and design without prior<br />

notice.<br />

34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!