7) Press the actuator paddle, check for continuity across the wires of the red connector.<br />
When the actuator paddle is engaged, the mechanical bin control switch is open.<br />
If closed, check that the actuator paddle is not restricted. Clean if necessary. See<br />
"IV.C.2.b) Mechanical Bin Control Cleaning." If the mechanical bin control switch still<br />
reads closed, replace the mechanical bin control.<br />
8) Reconnect the red connector to the control board RED K4 connector, then move the<br />
control switch to the "ICE" position. Turn on the power supply.<br />
9) Check that the green "BC CLOSED" LED on the control board is on.<br />
10) Allow the unit to cycle on. Press and hold the actuator paddle. The yellow "BC OPEN"<br />
LED should be on and the unit should shut down according to the chart below. If it does<br />
not, replace the control board.<br />
Cycle at<br />
Shutdown<br />
Mechanical Bin<br />
Control Activation<br />
Fill Cycle<br />
15 seconds after activation.<br />
Harvest Cycle At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated<br />
at the end of the harvest cycle.<br />
Freeze Cycle 15 seconds after activation if activated at least 15 seconds before the 5-minute short<br />
cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.<br />
Wire Harness Connector B<br />
(for upper unit)<br />
Single Unit Connection Detail<br />
Stacked Unit Connection Detail<br />
Upper Unit Wire Harness<br />
Connector B (not used)<br />
Bin Control<br />
Cable Connector<br />
Wire<br />
Harness<br />
Connector A<br />
Lower Unit Wire Harness<br />
Connector B<br />
Upper<br />
Unit Wire<br />
Harness<br />
Connector A<br />
Control Board<br />
Red K4<br />
Connector<br />
Actuator Paddle<br />
Control Board<br />
Red K4<br />
Connector<br />
Fig. 1<br />
Actuator Paddle<br />
41