8) Shutdown<br />

a) Thermostatic Bin Control: KM-1301SAH-E<br />

When the unit is running hold ice in contact with the thermostatic bulb, the<br />

thermostatic BC switch opens within 10 seconds, shutting down the unit (CB<br />

red "POWER OK" LED is off). The bin control is factory set, and generally<br />

no adjustment is required. However, adjustment may be needed in some<br />

conditions, particularly at higher altitude locations. Diagnosis: See "IV.C.1.<br />

Thermostatic Bin Control Check."<br />

b) Mechanical Bin Control: KM-1301SWH-E, KM-1301SRH-E<br />

See "IV.C.2.a) Mechanical Bin Control Check."<br />

Legend: BC–bin control; CB–control board; Comp–compressor; FM–fan motor; FMR–fan<br />

motor-remote; F/S–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.);<br />

LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve;<br />

WV–inlet water valve<br />