2. KM-1301SWH-E (water-cooled)<br />

APPROXIMATE ICE<br />

AMBIENT TEMP.<br />

WATER TEMP. (ºF/ºC)<br />

PRODUCTION PER 24 HR. (ºF/ºC) 50/10 70/21 90/32<br />

70/21 1330 603 1304 591 1239 562<br />

80/27 1310 594 1269 576 1189 539<br />

90/32 1304 591 1240 562 1165 528<br />

lbs./day kg./day 100/38 1281 581 1222 554 1096 497<br />

APPROXIMATE ELECTRIC<br />

CONSUMPTION<br />

70/21<br />

80/27<br />

90/32<br />

1780<br />

1780<br />

1780<br />

1780<br />

1780<br />

1780<br />

1799<br />

1810<br />

1806<br />

watts 100/38<br />

1790<br />

1786<br />

1830<br />

APPROXIMATE WATER<br />

70/21 1335 5.05 1425 5.40 1971 7.46<br />

CONSUMPTION PER 24 HR. 80/27 1404 5.31 1544 5.85 2324 8.80<br />

90/32 1425 5.40 1643 6.22 2335 8.84<br />

gal./day m 3 /day 100/38 1741 6.59 1805 6.83 2971 11.25<br />

FREEZING CYCLE TIME<br />

70/21<br />

80/27<br />

90/32<br />

31<br />

32<br />

32<br />

32<br />

33<br />

34<br />

34<br />

35<br />

36<br />

min.<br />

HARVEST CYCLE TIME<br />

100/38<br />

70/21<br />

80/27<br />

90/32<br />

33<br />

4.2<br />

3.8<br />

3.7<br />

34<br />

3.7<br />

3.0<br />

2.4<br />

38<br />

3.4<br />

2.9<br />

2.2<br />

min. 100/38<br />

3.1<br />

2.4<br />

2.1<br />

HEAD PRESSURE<br />

70/21 238 16.7 239 16.8 249 17.5<br />

80/27 239 16.8 240 16.9 256 18.0<br />

90/32 239 16.8 241 16.9 255 17.9<br />

PSIG kg/cm 2 G 100/38 244 17.2 244 17.2 267 18.8<br />

SUCTION PRESSURE<br />

70/21 50 3.5 51 3.6 52 3.6<br />

80/27 50 3.5 51 3.6 52 3.7<br />

90/32 51 3.6 52 3.7 53 3.7<br />

PSIG kg/cm 2 G 100/38 51 3.6 52 3.7 54 3.8<br />

TOTAL HEAT OF REJECTION FROM CONDENSER<br />

19,382 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />

TOTAL HEAT OF REJECTION FROM COMPRESSOR 2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]<br />

WATER FLOW FOR CONDENSER<br />

117 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]<br />

PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG<br />

Note:<br />

1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold<br />

should be used for reference only.<br />

2. We reserve the right to make changes in specifications and design without prior<br />

notice.<br />

33