KM1301SAH-E Service Manual - Hoshizaki
KM1301SAH-E Service Manual - Hoshizaki
KM1301SAH-E Service Manual - Hoshizaki
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
h) Float Switch Control (S5 dip switch 1)<br />
CAUTION<br />
Do not adjust. This must be left in the factory default position or the unit will not<br />
operate correctly.<br />
Factory set. S5 dip switch 1 allows for single or double float switch applications. The<br />
KM‐1301SAH-E, KM1301SWH-E, and KM-1301SRH-E use a single float switch.<br />
i) Refill Counter (S5 dip switch 2 through 5)<br />
CAUTION<br />
Do not adjust. These must be left in the factory default position or the unit will<br />
not operate correctly.<br />
Factory set. S5 dip switch 2 through 5 allows for refills during the freeze cycle.<br />
The KM‐1301SAH-E, KM1301SWH-E, and KM-1301SRH-E do not refill.<br />
D. Control Switch<br />
The control switch has three positions: "OFF" for power off, "ICE" for icemaking, and<br />
"WASH" to activate the water pump when cleaning and sanitizing.<br />