Series E Environmental Coils<br />
12-SIZE SERIES E COILS (For 12 Size Spool Valves Only)<br />
1.77<br />
44.9<br />
1.81<br />
46.0<br />
2.19<br />
55.6<br />
INCH<br />
MILLIMETRE<br />
2.19<br />
55.6<br />
3.03<br />
76.8<br />
3.03<br />
76.8<br />
EY<br />
IP69K Rated Coil<br />
Thermal Shock Dunk Test Rated Coil<br />
Metri-Pack ® 150 Connector<br />
(Mating Connector: Delphi Packard No. 12052641)<br />
EG<br />
IP65 Rated Coil<br />
DIN 43650 Connector<br />
EY Coil<br />
Part No.<br />
EG Coil<br />
Part No.<br />
Operating<br />
Voltage<br />
Resistance<br />
at 20°C<br />
Initial<br />
Current Draw<br />
Power<br />
Coil<br />
Weight<br />
6964012<br />
6956012<br />
12 VDC<br />
4.3 ohms<br />
2.8 amps<br />
33.6 watts<br />
1 kg. (2.2 lbs.)<br />
6964024<br />
6956024<br />
24 VDC<br />
17.5 ohms<br />
1.4 amps<br />
33.6 watts<br />
1 kg. (2.2 lbs.)<br />
6964036<br />
6956036<br />
36 VDC<br />
34.8 ohms<br />
1.0 amps<br />
36.0 watts<br />
1 kg. (2.2 lbs.)<br />
6964048<br />
6956048<br />
48 VDC<br />
67.0 ohms<br />
0.7 amps<br />
33.6 watts<br />
1 kg. (2.2 lbs.)<br />
% OF RATED VOLTAGE<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
CONTINUOUS DUTY OPERATING RANGE<br />
Minimum Voltage at <strong>the</strong> Coil Required for Pull-In<br />
32 cSt/150 ssu oil at 40°C<br />
Operating Range<br />
-40 -30 -20 -10 0 10 20 30 40 50<br />
AMBIENT TEMPERATURE (°C)<br />
60 70<br />
Retrofit Ordering Notes for 12-Size Coils<br />
Series E 12-size coils are designed for use on 12-size spool<br />
valves only. These models are: SV12-24, SV12-25, SV12-3x,<br />
and SV12-4x.<br />
Series E 12-size coils cannot be used with <strong>the</strong> following<br />
12 and 16 size poppet valves: SV12-20, SV12-21, SV12-22,<br />
SV12-23, SV16-20, SV16-21, SV16-22, and SV16-23. These<br />
valves use <strong>the</strong> Series E 10-size coils.<br />
Series E coils cannot be used with PV, ZL or EHPR series<br />
valves.<br />
3.400.4