®<br />
<strong>HYDRAFORCE</strong><br />
PWM (Pulse Train) Input<br />
DIMENSIONS<br />
2.50<br />
63.5<br />
2.10<br />
53.3<br />
INCH<br />
MILLIMETRE<br />
2.50<br />
63.5<br />
2.10<br />
53.3<br />
Setscrew<br />
Adjustments<br />
Span<br />
I-Max.<br />
Zero<br />
I-Min.<br />
Di<strong>the</strong>r<br />
Frequency<br />
TP9<br />
R50<br />
R32<br />
TP1<br />
TP8<br />
TP7<br />
Input Level LED<br />
Brightness increases as<br />
input signal increases.<br />
TP10<br />
L3<br />
R46<br />
TP6<br />
Ramp Up<br />
(Rising Edge)<br />
R49<br />
R48<br />
Ramp Down<br />
(Falling Edge)<br />
Di<strong>the</strong>r Level<br />
(Amplitude)<br />
R31<br />
TP5<br />
L2<br />
L1<br />
Power<br />
Okay LED<br />
TP3<br />
POW+<br />
POW–<br />
TP4<br />
+5V REF<br />
V IN<br />
TP2 AGND<br />
I IN<br />
ENABLE<br />
FGND<br />
SOL–<br />
SOL+<br />
Output Level LED<br />
Brightness increases as<br />
output amperage increases.<br />
Screw Terminal Connections<br />
for 16–30 AWG wire<br />
(+) Power<br />
(–) Power<br />
Not Used<br />
Not Used<br />
PWM Ground<br />
PWM In<br />
Enable<br />
Frame Ground<br />
(–) Solenoid<br />
(+) Solenoid<br />
Mounting Holes (4)<br />
0.156 (3.90) Dia.<br />
for #6 size screws<br />
(not supplied)<br />
Note: When Enable is<br />
connected to (+) Power<br />
or left open, <strong>the</strong> unit is<br />
enabled. When Enable<br />
is connected to (–) Power,<br />
<strong>the</strong> unit will be disabled.<br />
CONNECTIONS<br />
For Complete Set-Up Instructions, see page 3.560.1<br />
Basic Setup: Turn ramp screws fully counterclockwise to eliminate ramping.<br />
Use I-Min. screw to set minimum speed with minimum control input.<br />
Use I-Max. screw to set maximum speed with 100% of control input.<br />
PWM (Pulse Train) Control<br />
Supplied by User<br />
(+) Power<br />
(–) Power<br />
Not Used<br />
Not Used<br />
Ground<br />
PWM Input<br />
Enable<br />
Frame Gnd.<br />
(–) Coil<br />
(+) Coil<br />
Screw Terminal<br />
(+) Power<br />
(–) Power<br />
(+) 5V Reference<br />
Voltage In<br />
PWM Gnd.<br />
Current In<br />
Enable<br />
Frame Gnd.<br />
(–) Solenoid<br />
(+) Solenoid<br />
TO ORDER<br />
Part Number Output I-Min. Setting I-Max. Setting<br />
4000144 2000 mA Max. 0 to 500 mA 600 to 2000 mA<br />
3.525.2