®<br />

<strong>HYDRAFORCE</strong><br />

4–20 mA Input<br />

DIMENSIONS<br />

(+) Power Supply<br />

(–) Power Supply<br />

(+) 4-20 mA Input<br />

Signal Ground<br />

Red<br />

Black<br />

White<br />

Green<br />

Adjustments<br />

Under Cover.<br />

See Detail.<br />

1.34<br />

34<br />

ADJUSTMENTS DETAIL<br />

APPROX.<br />

79<br />

2 M<br />

3.36<br />

85<br />

Ramp<br />

Down<br />

Di<strong>the</strong>r<br />

Amplitude<br />

Ramp Up<br />

Di<strong>the</strong>r<br />

Frequency<br />

1.50<br />

38<br />

Minimum<br />

Current<br />

Maximum<br />

Current<br />

INCH<br />

MILLIMETRE<br />

M3<br />

1.34<br />

34<br />

.22<br />

5.5<br />

CONNECTIONS<br />

For Complete Set-Up Instructions, see page 3.560.1<br />

Basic Setup:<br />

Turn ramp screws fully counterclockwise to eliminate ramping.<br />

Use I-Min. screw to set minimum speed with minimum control input.<br />

Use I-Max. screw to set maximum speed with 100% of control input.<br />

4 to 20 mA Control<br />

Supplied by User<br />

(+) Power<br />

(–) Power<br />

(+) 4–20mA<br />

(–) 4–20mA<br />

Wire Color<br />

Red<br />

Black<br />

White<br />

Green<br />

TO ORDER<br />

Part Number Output I-Min. Setting I-Max. Setting Cable Length<br />

4000123 2000 mA Max. 0 to 500 mA 600 to 2000 mA 2 meters<br />

4000168 1600 mA Max. 0 to 350 mA 600 to 1600 mA 2 meters<br />

4000169 1200 mA Max. 0 to 150 mA 400 to 1200 mA 2 meters<br />

4000170 800 mA Max. 0 to 150 mA 300 to 800 mA 2 meters<br />

4000171 600 mA Max. 0 to 75 mA 200 to 600 mA 2 meters<br />