®<br />

<strong>HYDRAFORCE</strong><br />

0–5 VDC, 10K Pot or 0–20 mA Input<br />

DIMENSIONS<br />

For PCB (circuit board) only,<br />

refer to page 3.520.1<br />

4.50<br />

114.3<br />

4.00<br />

101.6<br />

(+) Power Supply Red<br />

(–) Power Supply Black<br />

5V Ref.<br />

Yellow/Red Stripe<br />

(+) 0–5V<br />

Yellow<br />

(–) V or mA Yellow/Black Stripe<br />

(+) 0–20 mA Yellow/Blue Stripe<br />

Enable<br />

Purple<br />

Frame Ground<br />

Shield<br />

(–) Coil<br />

Orange/Black Stripe<br />

(+) Coil<br />

Orange/Red Stripe<br />

Note: When Enable is connected<br />

to (+) Power or left open, <strong>the</strong><br />

unit is enabled. When Enable<br />

is connected to (–) Power,<br />

<strong>the</strong> unit will be disabled.<br />

Mounting Holes (4)<br />

0.250 (6.35) Dia.<br />

Cable Length<br />

See Ordering Info.<br />

INCH<br />

MILLIMETRE<br />

3.69<br />

93.7<br />

2.50<br />

63.5<br />

2.00 3.13<br />

50.8 79.4<br />

1.10<br />

27.9<br />

CONNECTIONS<br />

10K Potentiometer (Pot.) Control<br />

Supplied by User<br />

(+) Power<br />

(–) Power<br />

10K Pot.<br />

(+) Pot.<br />

(–) Pot.<br />

Not Used<br />

Enable<br />

Frame Gnd.<br />

(–) Coil<br />

(+) Coil<br />

For Complete Set-Up Instructions, see page 3.560.1<br />

Wire Color<br />

Red<br />

Black<br />

Yellow/Red Stripe<br />

Yellow<br />

Yellow/Black Stripe<br />

Yellow/Blue Stripe<br />

Purple<br />

Shield<br />

Orange/Black Stripe<br />

Orange/Red Stripe<br />

For Ei<strong>the</strong>r 0–20 mA or 0–5 VDC Control: Turn ramp screws fully counterclockwise<br />

to eliminate ramping. Use I-Min. screw to set minimum speed with minimum control<br />

input. Use I-Max. screw to set maximum speed with 100% of control input.<br />

0 to 20 mA Control<br />

Supplied by User<br />

(+) Power<br />

(–) Power<br />

Not Used<br />

Not Used<br />

(–) 0–20mA<br />

(+) 0–20mA<br />

Enable<br />

Frame Gnd.<br />

(–) Coil<br />

(+) Coil<br />

Wire Color<br />

Red<br />

Black<br />

Yellow/Red Stripe<br />

Yellow<br />

Yellow/Black Stripe<br />

Yellow/Blue Stripe<br />

Purple<br />

Shield<br />

Orange/Black Stripe<br />

Orange/Red Stripe<br />

0 to 5 VDC Control<br />

Supplied by User<br />

(+) Power<br />

(–) Power<br />

Not Used<br />

(+) 0–5V<br />

(–) 0–5V<br />

Not Used<br />

Enable<br />

Frame Gnd.<br />

(–) Coil<br />

(+) Coil<br />

Wire Color<br />

Red<br />

Black<br />

Yellow/Red Stripe<br />

Yellow<br />

Yellow/Black Stripe<br />

Yellow/Blue Stripe<br />

Purple<br />

Shield<br />

Orange/Black Stripe<br />

Orange/Red Stripe<br />

TO ORDER<br />

Part Number<br />

Part Number<br />

with 1.5 meter cable with 3 meter cable Output I-Min. Setting I-Max. Setting<br />

4000049 4000050 2000 mA Max. 0 to 500 mA 600 to 2000 mA<br />

4000173 4000177 1600 mA Max. 0 to 350 mA 600 to 1600 mA<br />

4000174 4000178 1200 mA Max. 0 to 150 mA 400 to 1200 mA<br />

4000175 4000179 800 mA Max. 0 to 150 mA 300 to 800 mA<br />

4000176 4000180 600 mA Max. 0 to 75 mA 200 to 600 mA<br />