COILS AND ELECTRONIC CONTROLS<br />

Series E Environmental Coils<br />

SERIES E COIL NUTS FOR VALVES WITH MANUAL OVERRIDE<br />

When ordering Series E coils for retrofit applications on valves with manual override, <strong>the</strong> coil nut (top nut)<br />

must be ordered separately, based on <strong>the</strong> specific model of <strong>the</strong> valve to be retrofitted. Additionally, valves<br />

with dual coils (SV08-47xM and SV10-47xM models) require a spacer to be installed between <strong>the</strong> two coils.<br />

The spacer must also be ordered separately. See page 3.400.6 for spacer information.<br />

1" HEX 1" HEX 1" HEX<br />

Coil Nut Part No.<br />

4526260<br />

For <strong>the</strong> following valves:<br />

Coil Nut Part No.<br />

4528150<br />

For <strong>the</strong> following valves:<br />

Coil Nut Part No.<br />

4527160<br />

For <strong>the</strong> following valves:<br />

SV08-20M<br />

SV08-22M<br />

SV08-24M<br />

SV08-25M<br />

SV08-26M<br />

SV08-3xM<br />

*SV08-4xM<br />

SV10-20M<br />

SV10-22M<br />

SV10-24M<br />

SV10-25M<br />

SV10-3xM<br />

*SV10-4xM<br />

SV12-20M<br />

SV12-22M<br />

SV16-20M<br />

SV16-22M<br />

SV38-20M<br />

SV38-22M<br />

SV38-24M<br />

SV38-25M<br />

SV38-26M<br />

SV38-3xM<br />

SV38-4xM<br />

SV58-20M<br />

SV58-22M<br />

SV58-24M<br />

SV58-25M<br />

SV58-26M<br />

SV58-3xM<br />

SV58-4xM<br />

SV08-47xM<br />

SV10-47xM<br />

*For SV08-47xM valves, use Coil Nut 4528150<br />

For SV10-47xM valves, use Coil Nut 4527160<br />

DESCRIPTION OF SERIES E COIL RATINGS<br />

IP69K: Coils with Metri-Pack ® connectors (EY option)<br />

Coils with Deutsch DT04-2P connectors (ER option)<br />

The coil is protected against intrusion of dust and high pressure<br />

water wash at 1450 psi (100 bar) with <strong>the</strong> source located 4 to 6<br />

inches (100 to 150 mm) from <strong>the</strong> coil.<br />

IP65: Coils with DIN 43650 connectors (EG option)<br />

Coils with Dual Spade connectors (ES option)<br />

Coils with Dual Lead Wires (EL option), and Coils with<br />

Leads and Wea<strong>the</strong>r-Pack ® Connector (EW option)<br />

The coil is protected against intrusion of dust and can withstand<br />

low-pressure water spray from a distance of 10 feet (3 meters).<br />

Thermal Shock Immersion Test:<br />

Coils with Metri-Pack ® connectors (EY option)<br />

Coils with Deutsch DT04-2P connectors (ER option)<br />

Known in <strong>the</strong> construction, agricultural and mobile equipment<br />

industries as a “<strong>the</strong>rmal shock dunk test,” <strong>the</strong> coil is heated for 2<br />

hours at 105°C, <strong>the</strong>n immediately immersed into 0°C water for 2<br />

hours. No water intrusion into <strong>the</strong> coil is allowed. This test is<br />

repeated for a total of five trials. The coil is <strong>the</strong>n tested for<br />

operational standards.<br />

Metri-Pack ® and Wea<strong>the</strong>r-Pack ® are registered trademarks<br />

of Delphi Packard Electric Systems<br />

3.400.7