Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />

wh Münzprüfer Berlin GmbH, Germany<br />

2.1.1. Technical Overview <strong>EMP</strong> 8x0.00 v6, 8x0.04 v6 und 8x0.13<br />

v6<br />

coin acceptance<br />

coin blocking<br />

output signals<br />

output pulse length<br />

coin return<br />

supply voltage<br />

supply current<br />

32 coin channels, 16 master and 16 slave channels<br />

Complete blocking via the machine controller. In addition,<br />

any individual coin, or group of coins can also be blocked<br />

through DIP switches.<br />

Individual coin blocking via coin output lines (Option /O)<br />

Six open collector output lines are available. Each output line<br />

can be freely assigned to any of the 16 master coin channels<br />

through programming.<br />

45 Volt / 500 mA<br />

1ms to 65 seconds, programmable<br />

The coin selector gives an active LOW signal on the coin<br />

reject line when the coin return button is pressed.<br />

10 V to 26 volts DC<br />

< 30 mA in standby, during coin acceptance briefly 300 mA.<br />

No power is needed for battery operated coin selectors in<br />

standby<br />

temperature range +10°C to +70 °C<br />

humidity classification according to DIN 40040: F<br />

coin sizes<br />

max. diameter x max. thickness: 32.5 x3.4 mm<br />

dimensions<br />

height x width x depth: 104 x 53 x 93.5 mm (without front<br />

plate)<br />

Options<br />

/A power supply connections are reversed, 7 coin output lines,<br />

no coin reject signal<br />

/B battery operation (standard)<br />

/C battery operation with inductive sensor<br />

/E extended temperature and humidity range<br />

–20°C to +70°C, humidity classification E/D:<br />

/F large coin funnel<br />

/I inventory impulse<br />

/N coin output signals inverted<br />

/O individual coin blocking via parallel lines<br />

/P no coin reject signal<br />

/R additional light barrier to observe coin return path<br />

/S preceding coin output signal<br />

/T teach mode (2 coin channels activated)<br />

/X control for external sorting flaps<br />

/Z additional external strimming detection<br />

version 1.40<br />

page 10/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6