03.03.2015 Views

Technisches Manual EMP 900

Technisches Manual EMP 900

Technisches Manual EMP 900

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />

wh Münzprüfer Berlin GmbH, Germany<br />

Fig. 12 programming of channel bank switching<br />

MODE 3 2 banks<br />

bank 1: programming of channels assignment to bank 1<br />

bank 2: all channels which are not assigned to bank 1<br />

For this mode please choose under “configuration“ – „general setting“ –<br />

„variants“ „non“ at channel switching. Activation of bank switching after<br />

MODE 3 is carried out by assigning at least one coin channel to bank 1.<br />

This is set under “configuration” – “blocking” in menu “external”. The<br />

assignment is effected by a “click” within the column “Bank 1” in the<br />

respective coin row.<br />

Fig. 13 Assignment of coin channels to coin bank for MODE 3<br />

Fig. 13 shows the assignment of coins to channel bank 1. The example<br />

above shows the assignment of coin channel 8 to 14 and 16 to bank 1<br />

and all other channels to bank 2.<br />

Switching between banks is carried out via the reject line of the <strong>EMP</strong><br />

connector. If the reject line is open, bank 1 is active, if set to LOW bank<br />

2 is active.<br />

The reject function of the coin selector is deactivated when in bank<br />

switching MODE 3. The reject may be pressed however no reject signal<br />

will be send via the parallel interface.<br />

version 1.40<br />

page 24/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6