Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />
wh Münzprüfer Berlin GmbH, Germany<br />
separation of foreign coins, the coin acceptance of the broad channel<br />
must be blocked (see chapter 3.4 Coin Blocking).<br />
16 out of the 32 coin channels are defined to be the master- and the<br />
other 16 to be slave channels. Any number of slave channels can be<br />
assigned to a master channel. They always have the same coin value,<br />
the same coin output lines and the same sorting path as the assigned<br />
master channel. In general they serve for the programming of<br />
adjustments with medium or narrow tolerances or differing coinage.<br />
The acknowledgement of an accepted coin is effected not before it has<br />
passed through the coin selector. The correct coin flow pass is<br />
monitored by light sensors.<br />
The measuring quality is primarily influenced by the<br />
steadiness of the coin passing through the measuring<br />
system, with the help of an integrated element which slows<br />
the coin down. The position of the coin selector and the<br />
insertion situation also influences the measuring quality.<br />
In general care should be taken to ensure an incline of 5° of<br />
the coin selector, to make certain that the coins can pass<br />
along the contact surface in an ideal way (see image 1).<br />
The coin insert should allow the coin to roll into the coin<br />
selector by a minimum of kinetic energy.<br />
Fig. 1<br />
<strong>EMP</strong> 8x0 v6 – Dimensions and Positioning<br />
version 1.40<br />
page 6/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6