Technisches Manual EMP 900
Technisches Manual EMP 900
Technisches Manual EMP 900
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />
wh Münzprüfer Berlin GmbH, Germany<br />
<strong>EMP</strong> 830.xx v6<br />
<strong>EMP</strong> 840.xx v6<br />
The second digit of the model number indicates the<br />
mechanical version and the two digits after the decimal point<br />
identify the electronic interface.<br />
connector for reject signal (<strong>EMP</strong> 800 and 890 only), ST2<br />
blocking switches<br />
9 to 16<br />
blocking switches<br />
1 to 8<br />
ccTalkconnector,<br />
ST7<br />
ST <strong>EMP</strong> (parallel)<br />
connector for external<br />
sorting flaps, ST4<br />
SCI-/ MDB connector (serial), ST1<br />
Fig. 2<br />
Location of connectors and control elements<br />
2. Technical Data<br />
2.1. Interfaces <strong>EMP</strong> 8x0.00 v6, 8x0.04 v6, 8x0.13 v6 and<br />
8x0.14 v6<br />
The <strong>EMP</strong> 8x0.00 v6 is a 6-output line coin selector. Any coin may be<br />
assigned to any parallel output channel and the length of the output<br />
pulse signal may be set from 1 ms to 65 seconds. Only 5 output<br />
version 1.40<br />
page 8/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6