Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />

wh Münzprüfer Berlin GmbH, Germany<br />

4.4.2. Assigning MDB error codes to cctalk error codes<br />

MDB Remarks ccTalk Remarks<br />

$90 Coin return button<br />

pressed<br />

254 Coin return button<br />

pressed<br />

$91 Subsequent coin 8 Subsequent coin<br />

$92 Coin jam 1 19 Coin too slow<br />

$93 Coin does not match<br />

parameter set<br />

1 Coin rejected<br />

$94 MDB blocking 2 Coin blocked<br />

$95 Coin jam 2 19 Coin too slow<br />

$96 DIP switch blocking 2 Coin blocked<br />

$97 Coin jam 3 19 Coin too slow<br />

$98 Coin jam 4 19 Coin too slow<br />

$99 Coin jam 6 19 Coin too slow<br />

$9A Rim detection error 1 Coin rejected<br />

$9B Lead detection 1 Coin rejected<br />

$9C Old: coin following to<br />

closely in TCAP1<br />

$9D Coin-on-a-thread<br />

detection<br />

255 Unknown error<br />

20 Coin on a thread<br />

manipulation<br />

$9E General blocking 2 Coin blocked<br />

$9F <strong>EMP</strong> busy 13 Not ready<br />

version 1.40<br />

page 46/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6