Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />
wh Münzprüfer Berlin GmbH, Germany<br />
Command<br />
Code Modifier Data from <strong>EMP</strong><br />
Extended Request 7Fh 21h 15 Bytes Z1 to Z15<br />
Z1 – Z4 Coin Release, 1 Bit per type, 1 = Unblock coin<br />
Z5 – Z6 Coin routed to cash box, 1 Bit per type, 1 = cash box<br />
Z7<br />
Cash box sorting shaft<br />
Z8 – Z15 Sorting shaft number of each type of coin; one nibble<br />
per type, beginning with type 1 in the upper nibble Z8<br />
The extended request is used to establish the actual coin release and<br />
sorting of all 32 channels. The sorting of the master and slave channels<br />
are always the same.<br />
Command<br />
Code Modifier Data from <strong>EMP</strong><br />
Coin Precision 7Fh FFH 13 Bytes Y1 to Y13<br />
Y1 – Y4 ASCII-Code for BDTA<br />
Y5<br />
Command Code 00H<br />
Y6 – Y13 Value for the desired acceptance band width for coin<br />
type 0 – 15 coded in half bytes.<br />
00H: wide<br />
01H: medium<br />
02H: narrow<br />
03H: very narrow<br />
0AH: tests factory-wise<br />
OEH: give back max. possible default setting<br />
OFH: no modification of current adjustments<br />
Data for VMC:<br />
Z1 – Z8<br />
current value for the acceptance band width coded for<br />
coin types 0 – 15 in half bytes<br />
version 1.40<br />