03.03.2015 Views

Technisches Manual EMP 900

Technisches Manual EMP 900

Technisches Manual EMP 900

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical <strong>Manual</strong> <strong>EMP</strong> 8x0.00/04/13/14 v6<br />

wh Münzprüfer Berlin GmbH, Germany<br />

Command<br />

Code Modifier Data from <strong>EMP</strong><br />

Extended Request 7Fh 21h 15 Bytes Z1 to Z15<br />

Z1 – Z4 Coin Release, 1 Bit per type, 1 = Unblock coin<br />

Z5 – Z6 Coin routed to cash box, 1 Bit per type, 1 = cash box<br />

Z7<br />

Cash box sorting shaft<br />

Z8 – Z15 Sorting shaft number of each type of coin; one nibble<br />

per type, beginning with type 1 in the upper nibble Z8<br />

The extended request is used to establish the actual coin release and<br />

sorting of all 32 channels. The sorting of the master and slave channels<br />

are always the same.<br />

Command<br />

Code Modifier Data from <strong>EMP</strong><br />

Coin Precision 7Fh FFH 13 Bytes Y1 to Y13<br />

Y1 – Y4 ASCII-Code for BDTA<br />

Y5<br />

Command Code 00H<br />

Y6 – Y13 Value for the desired acceptance band width for coin<br />

type 0 – 15 coded in half bytes.<br />

00H: wide<br />

01H: medium<br />

02H: narrow<br />

03H: very narrow<br />

0AH: tests factory-wise<br />

OEH: give back max. possible default setting<br />

OFH: no modification of current adjustments<br />

Data for VMC:<br />

Z1 – Z8<br />

current value for the acceptance band width coded for<br />

coin types 0 – 15 in half bytes<br />

version 1.40<br />

page 40/53 subject to technical modification <strong>EMP</strong>8x0.00/04/13/14 v6