3 Calculation<br />
3.1.3 Serviceability<br />
Figure 3.3: Dialog box Details, tab Serviceability<br />
With the options in the dialog section Deformation Related to, you can decide if the maximum<br />
deformations are related to the undeformed initial structure or to an imaginary connection<br />
line between member start and member end in the deformed system, which means<br />
the shifted ends of the member or member set.<br />
The limit deformations can be checked and, if necessary, adjusted in the dialog box National<br />
Annex Settings (see chapter 2.1.4, page 12).<br />
3.1.4 Fire Resistance<br />
This tab manages the settings for the fire protection design.<br />
Figure 3.4: Dialog box Details, tab Fire Resistance<br />
The Fire classification can be selected directly or defined individually by specifying a time for<br />
the fire duration.<br />
The dialog box National Annex Settings manages the standard-specific parameters that are<br />
significant for the fire protection design (see Figure 2.5, page 13).<br />