Typical failure modes of the material samples are(1) voids between layers, (2)<br />

disbonds between layers, (3) impurities or foreign material in the laminar<br />

interfaces and (4) significam irregularities (damage) to the geometric core<br />

structure. Typical defects in assembled sections are loose or damaged welds<br />

and rivets and erosion/corrosion between sections. often accompanied by<br />

material loss and thinning.<br />

Establishing test protocol involves determining acceptability of each part to be<br />

evaluated in terms of minimum size of void to be detected, minimum area of<br />

disbond that can be said to constitute a defect and any other void or disbond<br />

characteristic that is deemed significant. For this it is necessary to use known<br />

acceptable and known defective samples. Ideally, the defective samples<br />

furnished should include known defects of each classification and in the<br />

minimum sizes required to be detected and identified. When ideal defective<br />

samples are not available. it becomes necessary to synthesize flaws to<br />

simulate the minimum defects.<br />