Refrigeration<br />

Fast charging manifold<br />

Imperial's Kwik-Charger service manifold<br />

features a built-in dual-action control<br />

valve to charge systems up to eight<br />

times faster than<br />

conventional<br />

manifolds, with<br />

non-flutter gauges,<br />

visible faceplates<br />

for temperature<br />

and pressure<br />

readings. It<br />

can charge all refrigerants in a liquid state<br />

to a flow below compressor capacity.<br />

Stride Tool Inc. Circle no. 337<br />

Diagnostic module<br />

Heatcraft introduced its ServiceMate<br />

refrigeration diagnostic module at AHR<br />

Expo in Anaheim, Calif. in January. It<br />

features a single connection for all<br />

wiring. LED indicators show the status<br />

of each control circuit component,<br />

along with compressor, solenoid and<br />

input control voltage. The ServiceMate<br />

will become standard on all Heatcraft<br />

brands of single-dual compressor vertical<br />

condensing units and 3-40 hp semihermetic<br />

horizontal condensing units.<br />

Heatcraft Refrig. Circle no. 338<br />

R-22 replacement<br />

NU-22 from ICOR International is a<br />

direct replacement for R-22 in refrigeration<br />

applications. This non-toxic/nonflammable<br />

refrigerant<br />

is compatible with<br />

standard refrigerant<br />

oils and has ‘R-22-<br />

like’ operating characteristics<br />

in a broad<br />

application range for<br />

low, medium and<br />

high temperature systems. It is ASHRAE<br />

designated and safety classified A1.<br />

ICOR International Circle no. 339<br />

Product Profile<br />

Accurate refrigerant leak monitoring<br />

Innovative sensing device picks up<br />

AHR Expo technology award<br />

A Quebec-based instrument manufacturer drew considerable<br />

interest at the recent AHR Expo in Anaheim, Calif.<br />

with its infrared refrigerant gas transmitter.<br />

In fact the VA 301IRF from the Vulcain division of BW<br />

Technologies took top spot in the Tools and Instruments<br />

class in the AHR Expo Innovation Awards.<br />

The VA 301IRF is unique in that the sensor and transmitter<br />

are separate modules, permitting real-time remote<br />

sensing at distances up to 100 feet without the need for<br />

pumps and other mechanical parts. This served a real<br />

need in the industry that company sales and service reps<br />

kept hearing about out in the field, reported company<br />

president Guy Gervais, P. Eng.<br />

The sensing<br />

module functions<br />

on a diffusion<br />

basis and communicates<br />

concentration<br />

rates back to the<br />

transmitter on a<br />

Smiles all round: Guy Gervais, centre,<br />

accepts the award from ASHRAE<br />

president Richard Rooley, left, and<br />

ARI chairman David Pannier.<br />

Compatible with Pyxis<br />

Two medical-grade under-counter refrigerators<br />

are compatible with Pyxis medication<br />

inventory and dispensing systems<br />

with a door bracket that interfaces with<br />

the Pyxis lock box when refrigerated<br />

medication is selected: REF4-ADA is<br />

31.5-in. high and 4.0 cu.ft. capacity; REF5<br />

Product Profile<br />

Canadian firm launches R-22 replacement<br />

An Ontario-based company has launched a retrofit replacement for HCFC R-<br />

22 in air conditioning applications. SP22C from Protocol Resource<br />

Management, Aurora, Ont., does not require a system oil change and works<br />

well with the existing mineral oil. The company was granted a U.S. patent on<br />

Dec. 30.<br />

The pressure, temperature and operating characteristics of<br />

SP22C are designed to match R-22 in AC applications. It<br />

achieves this through a formulation of HFCs and oil miscibility<br />

additives.<br />

The manufacturer reports that performance in an optimized<br />

system exceeds that of R-22. In a direct retrofit<br />

application with no system modifications, SP22C performed<br />

within four per cent of the original equipment manufacturer’s<br />

capacity rating. In retrofits, the drier and TX valve<br />

should be replaced and the super heat should be adjusted.<br />

SP22C is non-flammable and has been tested for flammability<br />

according to UL2182.<br />

Company president James Flowers notes that SP22C<br />

fulfils a need in the refrigeration market. “Current OEM<br />

replacements for R-22, such as R-410a, are unsuitable<br />

for retrofit applications because of significantly higher<br />

operating pressures and the requirement for additional<br />

safety approvals for system components.”<br />

This new refrigerant<br />

from<br />

Protocol provides<br />

a replacement<br />

for R-22 in retrofit<br />

applications<br />

Protocol will feature its SP22C R-22 replacement refrigerant at the <strong>CMX</strong><br />

show in Toronto March 26-27.<br />

Protocol Resource Mgt. Circle no. 343<br />

RS-485 communication<br />

bus,<br />

eliminating issues<br />

related to sample<br />

draw systems such<br />

is 34.5-in. with 4.8 cu.ft., stainless construction,<br />

locking door latch, adjustable<br />

temperature set points, digital temperature<br />

display and are UL, cUL and NSF<br />

certified.<br />

Follett Corp. Circle no. 340<br />

Frictionless chillers<br />

McQuay chillers are now available<br />

with frictionless, oil-free centrifugal<br />

compressors from Turbocor, Montreal.<br />

These variable speed units feature<br />

Distributors of<br />

these Quality<br />

Products !<br />

General Electric<br />

Zoneline Horizontal & Vertical Series P.T.A.Cs<br />

Room Air Conditioners<br />

Applied Comfort Products<br />

Comfortline Series P.T.A.C’s<br />

Keeprite Seasonal & Chromalox Replacements<br />

Adirondack Aire / Cold Point<br />

Replacement Water Source Heat Pumps<br />

Xpediair<br />

Quality Fan Coil Cooling Solutions<br />

MovinCool<br />

Portable Spot Coolers<br />

Delonghi Pinguino<br />

Portable Room Air Conditioners<br />

Panasonic<br />

Super Quiet Ventilation Fans<br />

Sharp<br />

Plasmacluster Air Purification<br />

GORDON R. WILLIAMS<br />

C O R P O R A T I O N<br />

3250 Ridgeway Dr. Unit # 9<br />

Mississauga, Ontario L5L 5Y6<br />

Ph. 905-820-1400 1-888-209-0999<br />

www.williamshvac.com<br />

as dwell time.<br />

The single beam<br />

dual sensor provides<br />

stable and<br />

accurate monitoring<br />

of refrigerant<br />

leaks far exceeding<br />

ASHRAE 15<br />

and International<br />

Mechanical Code<br />

requirements.<br />

And the transmitter<br />

module provides<br />

remote readitor<br />

allows accurate and stable re-<br />

The Vulcain infrared refrigerant monouts<br />

instantly mote monitoring of refrigerant leaks.<br />

through its backlit<br />

LCD and LED alarm status display.<br />

This unit is easily customized to specific projects.<br />

Options include: analog outputs, modbus, three relays,<br />

strobe light and horn. The unit is compatible with<br />

Vulcain’s VA201C controller.<br />

Gervais told P&<strong>HVAC</strong> that the company has had to<br />

shift into overdrive to keep up with demand since the<br />

product was introduced last September. “It’s complete<br />

turn-key solution for the mechanical room,” he added.<br />

Vulcain Div., BW Technologies Circle no. 342<br />

magnetic bearings<br />

and digital electronic<br />

controls.<br />

They offer full-load<br />

performance as low<br />

as .62 kW/ton, part<br />

load as low as .375<br />

kW/ton, sound<br />

pressure ratings as low as 77 dBA,<br />

lower maintenance costs and operate<br />

with environmentally friendly R-134a<br />

refrigerant.<br />

McQuay International Circle no. 341<br />

www.astravan.com info@astravan.com<br />

Circle Number 125 for More Info Circle Number 126 for More Info<br />

www.plumbingandhvac.ca March/April <strong>2004</strong> – <strong>Plumbing</strong> & <strong>HVAC</strong> Product News 25