Dimensions<br />

<strong>TeSys</strong> enclosed starters<br />

2<br />

D.O.L. starters for motor control<br />

2.2 to 45 kW, with isolating device<br />

LE4-K06 and K09<br />

LE8-K06 and K09<br />

31<br />

LE4-D09 to D35<br />

LE8-D09 to D35<br />

165<br />

19 20 84<br />

120<br />

175<br />

c1<br />

150<br />

(1)<br />

c1<br />

348<br />

= 330<br />

=<br />

= =<br />

186 31<br />

c1<br />

c1<br />

LE4-K LE8-K LE4-D LE8-D<br />

Standard version 146 146 Standard version 175.5 182<br />

Version A05 – 139 Version A04 167 167<br />

Version A05 175.5 175.5<br />

(1) For LE8 only.<br />

LE4-D406 to D656<br />

287<br />

195 =<br />

c1 = 225 =<br />

367<br />

=<br />

31<br />

c1<br />

Standard version 201<br />

Version A04 190<br />

Version A05 201<br />

LE2-D406 to D806<br />

LE4-D806<br />

= a-75<br />

=<br />

31<br />

400 (1)<br />

342,5<br />

350<br />

4xM8x25<br />

325 =<br />

=<br />

LE2-<br />

a<br />

D406, D506, D656 300<br />

D806 400<br />

LE4-<br />

a<br />

D806 400<br />

202<br />

c1<br />

(1) + 14 mm with blanking plugs.<br />

a-50<br />

a<br />

a+57,5<br />

c1<br />

LE2-D LE4-D<br />

Standard version 218 218<br />

Version A05 218 218<br />

Version A11 – 218<br />

Knock-outs or blanking plugs for cable glands<br />

Type of enclosure At top At bottom<br />

PG ISO PG ISO<br />

LE4 and LE8-D09 to D35 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or<br />

2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I 2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I<br />

LE2-D09 to D35 1 x 16 or 2 x 21 2 x 20 I or 2 x 25 I 2 x 16 or 2 x 21 2 x 20 I or 2 x 25 I<br />

LE2-D406 and LE4-D406 1 x 13 and 1 x 21 1 x 20 I and 1 x 25 I 1 x 13 and 2 x 21 1 x 20 I and 2 x 25 I<br />

LE1-D506 to D656 and LE4-D506 and D6561 x 13 and 1 x 29 1 x 20 I and 1 x 32 I 1 x 13 and 2 x 29 1 x 20 I and 2 x 32 I<br />

LE2-D806 and LE4-D806 1 x 13 and 1 x 36 1 x 20 I and 1 x 40 I 1 x 13 and 2 x 36 1 x 20 I and 2 x 40 I<br />

LE4-K, LE8-K 2 x 13 and 2 x 16 4 x 20 I 2 x 13 and 2 x 16 4 x 20 I<br />

References :<br />

pages 24103/2 and 24103/<br />

3<br />

Schemes :<br />

page 24104/3<br />

24104_Ver2.10-EN.fm/2<br />

Schneider Electric