01.07.2015 Views

TeSys protection components - Trinet

TeSys protection components - Trinet

TeSys protection components - Trinet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Schemes<br />

Installation system<br />

Tego Power for motor power-starter <strong>components</strong><br />

Control-command circuit diagrams for a direct starter<br />

(conforming to standards "Low voltage installation regulations" C 15-100 and "Machine safety" NF EN 60205-1 standards)<br />

1 - Without APP-1DppppD connection blocks and with frontal auxiliary contact 2 - With APP-1DppppD connection blocks and frontal auxiliary contact<br />

GV2-AE20<br />

GV2-AE20<br />

3 - With forced local start, cable on shunt (3) - (without APP-1ppppD connection<br />

blocks and with frontal auxiliary contact GV2-AE20). The cabling of the shunt for<br />

a forced local start is equally possible with connection blocks APP-1ppppD<br />

A Tego Power sub-base<br />

B Communication module<br />

X1, X4 HE 10 connector, removable terminal block (see below)<br />

Q1 Thermal-magnetic motor circuit-breaker<br />

(1) Km1 : APP-1ER or APP-1ES interface relay<br />

(2) KM1 : contactor coil<br />

(3) External shunt on the lower connection block. It can be used to connect an external input.<br />

(4) To communication module<br />

(5) Maximum control voltage of contactor coils c 48 V/a 240 V<br />

(6) Control unit (option) for forced local start<br />

(7) 2-position “Auto-Manual” selector switch (option)<br />

APP-1CE and APP-1CV communication modules<br />

24 V power supply :<br />

V In : inputs<br />

V Out : outputs<br />

A<br />

B<br />

X1<br />

X2<br />

X3<br />

X4<br />

Tego Power sub-base<br />

Communication module<br />

Removable terminal block for connection of circuit-breaker contacts 1 to 8 (terminals QI.1 to QI.8)<br />

Removable terminal block for connection of contactor contacts 1 to 8 (terminals KMI.1 to KMI.8)<br />

Removable terminal block for connection of interface relays 1 to 8 (terminals KmO.1 to KmO.8)<br />

Removable terminal block for the I/O 24 V supply<br />

Presentation, description :<br />

pages 15010/2 and 15010/3<br />

Selection :<br />

pages 15011/2 and 15011/3<br />

Characteristics :<br />

pages 15013/2 to 15013/5<br />

References :<br />

pages 15014/2 and 15014/3<br />

5016 Ver4.00-EN.fm/2 Schneider Electric

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!