01.07.2015 Views

TeSys protection components - Trinet

TeSys protection components - Trinet

TeSys protection components - Trinet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Schemes<br />

<strong>TeSys</strong> enclosed starters<br />

2<br />

Star-delta starters<br />

7.5 to 75 kW, with isolating device<br />

LE6-D09 to D18<br />

LE6-D09 to D18<br />

– Q1<br />

1/L1<br />

2<br />

3/L2<br />

4<br />

5/L3<br />

6<br />

2<br />

U1<br />

4<br />

V1<br />

6<br />

W1<br />

A<br />

Q1<br />

Q1<br />

1<br />

3<br />

5<br />

1<br />

3<br />

5<br />

1<br />

3<br />

5<br />

O<br />

– KM2<br />

– KM3<br />

– KM1<br />

2<br />

4<br />

U2<br />

6<br />

V2<br />

2<br />

4<br />

6<br />

W2<br />

U1<br />

2<br />

4<br />

V1<br />

6<br />

W1<br />

l<br />

– KM2<br />

U2<br />

V2<br />

W2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Recommended<br />

cabling for<br />

reversal of<br />

motor rotation<br />

(standard motor,<br />

viewed from shaft<br />

end).<br />

– KM1<br />

– KM2<br />

– KM2<br />

– KM3<br />

– KM1<br />

– KM1<br />

A1<br />

– KM2<br />

A1<br />

– KM3<br />

A1<br />

B<br />

A2<br />

A2<br />

A2<br />

LE3-D326 to D806<br />

LE3-D326 to D806<br />

1/L1<br />

3/L2<br />

5/L3<br />

2<br />

4<br />

6<br />

A<br />

– Q1<br />

2<br />

4<br />

6<br />

U1<br />

V1<br />

W1<br />

– F1<br />

Q1<br />

1<br />

3<br />

5<br />

1<br />

3<br />

5<br />

1<br />

3<br />

5<br />

– KM2<br />

– KM3<br />

– KM1<br />

U2<br />

V2<br />

W2<br />

– S1<br />

21<br />

2<br />

4<br />

6<br />

2<br />

4<br />

6<br />

2<br />

4<br />

6<br />

22<br />

Remote<br />

control<br />

13<br />

U1<br />

V1<br />

W1<br />

1<br />

3<br />

5<br />

l<br />

14<br />

– KM2<br />

U2<br />

V2<br />

W2<br />

2<br />

4<br />

6<br />

Recommended<br />

cabling for<br />

reversal of<br />

motor rotation<br />

(standard motor,<br />

viewed from shaft<br />

end).<br />

– KM1<br />

– KM2<br />

– KM2<br />

– KM3<br />

– KM1<br />

– KM1<br />

A1<br />

– KM2<br />

A1<br />

– KM3<br />

A1<br />

B<br />

A2<br />

A2<br />

A2<br />

References :<br />

pages 24108/2 and 24108/3<br />

Schneider Electric<br />

Dimensions :<br />

page 24109/2<br />

Connections A B<br />

220 V, 230 V, 240 V LE6-D09 and D12 L3 Neutral<br />

LE6-D18 to LE3-D806 L3 Neutral terminal<br />

380 V, 400 V, 415 V, 440 V All products L3 L1<br />

Other voltages LE6-D09 to D18 Terminal 1 Terminal 2<br />

LE3-D326 to D806<br />

Direct connection<br />

24109_Ver2.10-EN.fm/3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!