Water Supply Master Plan Update<strong>Sarasota</strong> CountyWater Storage Tank Asset InventoryTank ID Description Site AddressBaseElevation 1 (ft)Height 1 (ft)EVT1 Elevated Tank #1 1850 Wendell Kent Rd 34 155 2.0 100 115 155 A36 Steel Pitt-Des Moines 1997Size 1(MG)Diameter 1(ft)Disinfection RecirculationWater Levels 1 TankTank Year ofYear of Last Structural EvaluationConstruction Manufacturer ConstructionSystem PipingMin (ft) Max (ft) (Yes/No) (Yes/No)Had coating inspection ~3 years ago. Aredeveloping a program to inspect all tanksevery 5 years per new DEP Rules.NoNoGeneral FacilityConditionGood - Will need newcoating within 10yearsRemarksEVT2 Elevated Tank #2 2602 Mall Dr No drawings 0.25 No drawingsPitt-Des Moines 1969Was repaired in summer 2004 to securetower to base.NoNoPoor. Needs repair -structural evaluation,new coating, etc.Acquired from Florida Cities Utilities in 2003. The tank isclosed from the system by 3 valves. There is some leakageand staff has to empty the tank every few months.GST1 University Ground Storage Tank 3120 University Pkwy 34.7 32.3 3.0 125See note #1PrestressedCompositeCrom 1984Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.YesNoGood - Has poormixing when leveldrops to < 20'Location of chemical feed may not be optimum. Chlorinefeeds at base, and ammonia feeds at top ~90 degrees fromchlorine. Operators keep water level at 25-29' to preventshort-circuiting and time for mixing.GST-CCarlton Ground Storage Tank1255 T. Mabry CarltonPkwy, Venice24.5See note#15.0 160 25.5 57.58PrestressedCompositeCrom 1995Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No Good Turns over 2.5 times per day.GST-VG1Venice Gardens GroundStorage Tank #11350 Jacaranda Blvd,VeniceSee note #1See note#11.0 85See note#123.42PrestressedCompositeCrom 1974Cleaned and inspected by Crom in 2005.Coated the baffle walls inside of tank.No No GoodGST-VG2Venice Gardens GroundStorage Tank #21350 Jacaranda Blvd,VeniceSee note #1See note#12.0 107See note#129.75PrestressedCompositeCrom 1983Cleaned and inspected by TankEngineering in 2005.No No GoodGST-VG3Venice Gardens GroundStorage Tank #31350 Jacaranda Blvd,Venice15.91See note#12.0 107 15.91 45.66PrestressedCompositeCrom 2004 n/a - New tank. No No New Construction completed recently. Not yet in service.GST2 PS2 Ground Storage Tank 1001 S. Beneva Road See note #1 21 1.0 90See note #1PrestressedCompositeCrom 1975Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No Good Not in service. Taken offline approximatley 10 years ago.GST3-1 PS3 Ground Storage Tank #1 5508 Ruby Place See note #1 23.5 1.5 105See note #1PrestressedCompositeCrom 1975Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No GoodGST3-2 PS3 Ground Storage Tank #2 5508 Ruby Place See note #1 23.5 1.5 105See note #1PrestressedCompositeCrom 1975Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No GoodRarely in service. Distribution system staff have troublekeeping chlorine residuals in the tanks. Tanks areregualarly cleaned and maintained. The tankare set up to beonline when/if needed.GST3-3 PS3 Ground Storage Tank #3 5508 Ruby Place See note #1 23.5 1.5 105See note #1PrestressedCompositeCrom 1983Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No GoodGST5 PS5 Ground Storage Tank 5949 Proctor Road 32.5 29.17 2.5 120See note#162.08PrestressedCompositeCrom 1984Cleaned, painted, inspected in Summer2004No No GoodThis tank is only used occasionally for watering days.Operators have problems keeping a chlorine residual in thetank.GST6 PS6 Ground Storage Tank 4201 Vamo Road 14.75 35 3.0 120See note #1PrestressedCompositeCrom 1991Operators did not know exact date of lastinspection. However, staff are developing aprogram to inspect all tanks every 5 yearsper new DEP Rules.No No GoodThis tank is normally not used, but can be put into servicewhen needed.SKT1 2SKT2 2Siesta Key Utilities AuthorityGround Storage Tank #1Siesta Key Utilities AuthorityGround Storage Tank #25200 Oakmont Place 5 20 0.75 80 5 25 Concrete n/a 1967 n/a Yes n/a5200 Oakmont Place 5 28 2.0 110 5 33 Concrete n/a 1972 n/a Yes n/aUnknown, did nothave access to plantsite.SKT3 2Siesta Key Utilities AuthorityGround Storage Tank #36647 Midnight PassRoadn/a n/a 1.0 n/a n/a n/a Concrete n/a n/a n/a No n/aUnknown, did nothave access to tank.Tank has not been used for many years.Notes: 1 Some record drawings do not indicate elevations or minimum and maximum water levels. Only dimensions shown on drawings are included in this table.2 Information provided by Siesta Key Utilities Authority.H-1