Water Supply Master Plan Update<strong>Sarasota</strong> CountyPump Station Asset InventorySite InformationMotor Information 1Pump StationPump IDPump DescriptionMotor ManufacturerSerial NumberMotor hpVoltsAmpsMotor Speed(rpm)General FacilityConditionRemarksPS1 PS1-BP1 Booster Pump #1 US Motors H020-205Z043R297M 150 460 171.7 1775 GoodPS1 PS1-BP2 Booster Pump #2 US Motors C603601-827 150 460 183 1775 GoodThe booster pumps usually do not run. The pressure from Manatee County (65-70 psi) issufficient for the <strong>Sarasota</strong> County system. If pressure drops to less than 62 psi, the boosterpumps start. They operate to keep the pressure between 62 and 65 psi when needed.Operators see little pressure drop through the pump station, so pressures entering <strong>Sarasota</strong>County are approximately 65 psi.PS1 PS1-HSP1 High Service Pump #1 US Motors G61370/V07V1670083R 75 230/460 172/86 1780 GoodPS1 PS1-HSP2 High Service Pump #2 US Motors 5K405AL2100 125 460 148 1780 GoodDon't have automatic start and stop set points for pumps. They are operated manually at thedecision of the operators, usually based on keeping water quality at certain levels (turbidity