10.07.2015 Views

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Instruction Manual <strong>MM850402</strong> ed. <strong>06</strong>Accuracies and rangesParameter Sensor type Range Resol. MaxAccuracyresponceO 2 Electrochemical fr<strong>om</strong> 0 to 25.0% 0.1% 20 sec. ±0.1% vol.COH 2 c<strong>om</strong>pensated upto 1000ppmElectrochemical fr<strong>om</strong> 0 to 8000 ppm 1 ppm 50 sec.±10 ppm 2000 ppmCO Electrochemical fr<strong>om</strong> 0 to 20.000 ppm 1 ppm 40 sec.±10 ppm 2000 ppmNO Electrochemical fr<strong>om</strong> 0 to <strong>4000</strong> ppm 1 ppm 40 sec. ±5 ppm 125 ppmNO 2 Electrochemical fr<strong>om</strong> 0 to 1000 ppm 1 ppm 50 sec. ±5 ppm 125 ppmNO x Calculated fr<strong>om</strong> 0 to 5000 ppm 1 ppmSO 2 Electrochemical fr<strong>om</strong> 0 to <strong>4000</strong> ppm 1 ppm 40 sec. ±5 ppm 125 ppmCO% Electrochemical fr<strong>om</strong> 0 to 10.00 % 0.01% 50 sec. ±0.01% up to 0.2%±4% rdg > 0.2%CO 2 Calculated fr<strong>om</strong> 0 to 99.9% 0.1 %Tair Pt100 fr<strong>om</strong> -10 to 100 °C 0.1 °C ±(0.2% rdg+0.15°C)Tgas Tc K fr<strong>om</strong> -10 to 1000 °C 0.1 °C ±(0.3% rdg+0.3°C)∆T Calculated fr<strong>om</strong> 0 to 1000 °C 0.1 °CTflow Tc K fr<strong>om</strong> -10 to 100 °C 0.1 °C ±(0.3%rdg+0.3°C)Treturn Tc K fr<strong>om</strong> -10 to 100 °C 0.1 °C ±(0.3% rdg+0.3°C)Pressure/Draft∆PPiezo -10hPa to +100 hPa 0.01 hPa ±3 Pa up to 300 Pa±1% rdgExcess air Calculated fr<strong>om</strong> 1.00 to infinity 0.01Efficiency Calculated fr<strong>om</strong> 0 to 99.9% 0.1 %<strong>Gas</strong> speed Pitot tube Fr<strong>om</strong> 0 to 100.0 m/s 0.1 m/sSmoke index External pump fr<strong>om</strong> 0 to 9• Technical units and ranges can be converted directly fr<strong>om</strong> ppm to mg/Nm 3 , mg/kwh and fr<strong>om</strong> hPa to mmH 2 O, mbar orinH 2 O.• The relative accuracy shown are expressed as absolute or % of rdg errors at -5°C to +40°C ambient temperature.• The maximum response time shown is referred to 90% signal changes.• The pressure relative accuracy shown is valid only after the auto-zero procedure.N.B.: Specifications may change without notice.11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!