10.07.2015 Views

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Instruction Manual <strong>MM850402</strong> ed. <strong>06</strong>2.8 Smoke MeasurementSmoke index measurement is done by using an external hand pump (supplied as an accessory), the results canbe stored in memory and printed in the report.2.9 Remote Temperature ProbeA remote Pt100 probe is available for c<strong>om</strong>bustion air temperature measurement fr<strong>om</strong> –10°C to 100°C. This probeis strongly rec<strong>om</strong>mended mainly in forced air boiler to obtain an accurate calculation of the efficiency.2.10 T+RH% ProbeOptional probe for simultaneous measurement of ambient temperature and relative humidity (%RH) for c<strong>om</strong>fortindex calculations.2.12 Ambient CO ProbeOptional probe to monitor CO concentration and therefore safety condition in the boiler ro<strong>om</strong>. The instrumentgives acoustic and visual alarms if the set limit (according to the OSHA rec<strong>om</strong>mendation) are exceeded.2.12 Natural <strong>Gas</strong> ProbeOptional probe to monitor CH 4 and natural gas concentration and detect and locate the position of a gas leak intothe d<strong>om</strong>estic pipe network.2.13 Leakage Checking ModeTo check gas network tightness using a pressure decay method a pro<strong>gr</strong>ammable interval time. It uses the internalpressure sensor and a Eurotron leakage procedure.2.14 External Pa Pressure Sensor (Uni<strong>Gas</strong> <strong>3000</strong>+)The Uni<strong>Gas</strong> <strong>3000</strong>+ only can use the external Pa sensor for pressure and Draft (BB830025). The sensor is aunique vacuum meter with higher precision (± 0,5 Pa) and resolution (0,1 Pa) specification if c<strong>om</strong>pared to theinternal sensor ones. This sensor is useful to measurements that respond to the UNI10845.2.15 Burner Pressure ProbeA 1 meter 8x4mm silicon hose (cat. EE<strong>3000</strong>88) is used to check the pressure inside the burner when you areinstalling the heating system.2.16 Pitot tubeThe <strong>3000</strong>-<strong>4000</strong> series analyzer can be connected to a pitot tube for gas speed measurements.2.17 Calibration CertificateEach <strong>3000</strong>-<strong>4000</strong> series portable gas analyzer, is factory calibrated and certified against Eurotron Standards, thatare periodically certified by an International recognized Laboratory, and shipped with a Certificate of Calibrationstating the n<strong>om</strong>inal and actual values and the deviation errors.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!