10.07.2015 Views

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

MM850402-06 Gas Analysers 3000-4000 - om.gr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Instruction Manual <strong>MM850402</strong> ed. <strong>06</strong>Error message Problem SolutionsCalc Err Parameter calculation error. The instrument cannot perform thecalculations correctly. Check and solve theother error conditions.Probe Er The external Rtd probe isdisconnected or damaged.RJ Err Internal temperature referencedamaged.Connect or replace the externaltemperature probe.Return the instrument to Eurotron formaintenanceOver Overrange condition The problem is solved aut<strong>om</strong>atically whenmeasure return inside the rangeUnder Underrange condition The problem is solved aut<strong>om</strong>atically whenmeasure return inside the range-------- No calculation available The instrument cannot perform thecalculations. Check and solve the othererror conditions. (e.g. O 2 >18%).CO sensor excluded by electro-valve Aut<strong>om</strong>atic CO sensor protection is active.ExcludedPerform one or more autozero cycles infresh air.Tc Error The thermocouple is disconnected or Connect or replace the temperature probe.damaged.Tsens Er Cell c<strong>om</strong>pensation error Return the instrument to Eurotron formaintenance.Perform one or more autozero cycles inZero Err The autozero procedure is failing fresh air. If the problem remain, Return theinstrument to Eurotron for maintenance.Sens. Er Broken cell Return the instrument to Eurotron formaintenance.No meas. Empty MemoryNo sens. The cell is non installedNo probe No external probe connected onmini-din connector.Connect or replace the temperature probe.10.3 Set-Up MenuConfiguration menu is protected by a password. This procedure menu allows the operator to change s<strong>om</strong>einternal parameter values: Date and time internal clock, c<strong>om</strong>munication baud rate, autozero time and leak testtiming.Follow the procedure below to activate the procedure:• Switch the instrument off• Press and keep the [SETUP] key down; press the [ON/OFF] key.• The analyzer will switch on. A password input page will be displayed. Insert the password code “0011” andpress the [ENTER] key. The following page will displayed:SET-UPPag.1ClockSerial PortAnalysis par.P decay TimeNEXT–• Press the [NEXT] (F1) key to change menu page.56

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!