Instruction Manual <strong>MM850402</strong> ed. <strong>06</strong>MEASUREP DECAY LEAK TESTGAS LEAK TESTAMBIENT COENVIRON. TEMP/HUM–ESCAPE• Use the [] and [] keys to move the cursor symbol to “P DECAY LEAK TEST” option.• Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.SELECT TEST0.3 mmH2OParametersTest Type : ASTART TESTZEROESCAPE–• Select "Test type" and select test type "B"• Select "START TEST" to begin the testP 1:P 2:P 3:P 4:235.5 hPa235.7 hPa235.8 hPa235.0 hPa∆P:0.5 hPaTest B: 160sNEXTESCAPE–• In this test there are four Pressures with times various. This times can be set like described in the para<strong>gr</strong>aph10.3.4 in this manual.• Press the button Print for the test resultLEGENDEurotron S.p.AUnigas <strong>3000</strong>+Serial Number 000P1-P2-P3-P4 mmH 2 O measures of pressure∆P : Difference of pressure∆T : Difference of TimeDate: 00/00/0000Time: 00:00P DECAY LEAKTEST BP1: 0.0 mmH 2 OP2: 0.0 mmH 2 OP3: 0.0 mmH 2 OP4: 0.0 mmH 2 O∆P :0.0 mmH 2 O∆t :310 sPLANT TAGPlant 1BOILER TAGBoiler 1CUSTOMERName: Cust<strong>om</strong>er 1Addr.:City :Tel.: :Note : ---------------------------------------41