MZT-500SERIES 810 — Micro Zone Test System You can obtain the indentation factor, which is related tothe hardness value (partially) shown in Martens hardnesstest (ISO14577) and Young’s modulus. Deformationcharacteristics in the load, dwell, and unload phases arealso obtainable for use in determining properties of thespecimen material. are supported. (MZT-512 and 522 only) the effect of external vibrations on measurements. available. maximum of 20mm with a measurement resolution of0.1nm. electromagnetically for evaluation of material properties insubmicroscopic areas. dust and wind.When it comes to evaluating mechanicalproperties of ultra-small regions of ultrafinespecimens, the MZT-500 Series aremost powerful in the fields of researchand development and quality control.The MZT-500 can evaluate mechanicalproperties, which the conventional hardnesstesting machines for fine specimens cannotmeasure, such as: various CVD and PVDdepositedor generated films, including ionplatedfilms; hardness of ultra-fine crosssections;bonding mechanical properties;and wear mechanical properties of carbonfiber, glass fiber, whisker, etc.SPECIFICATIONSModel No. MZT-511 MZT-512 MZT-521 MZT-522Order No. 810-809A 810-810A 810-811A 810-812ABasic system ✔ ✔ ✔ ✔Data analysis / controldevice✔ ✔ ✔ ✔Video linemeasurement software — ✔ — ✔Automatic multi-pointmeasurement device— — ✔ ✔Test force range0.098 to 980.7mNTest force loading device Control resolution0.916μNLoading speed0.1 to 100mN/sIndenter indentation depth Measurement range0 to 20μmmeasurement device Measurement minimum unit 0.1nmIndenter Type Bercovici triangular pyramid indenterCamera1/3 inch black and white (410,000 pixels)Sample surface observationdeviceMonitor9 inch black and whiteObjective (monitor magnification) 100X (2600X), 10X (260X)Specimen dimensionsMaximum dimension90mmMaximum depth90mm (From the center of the indenter axis)Indenter indentation test (with an preliminary test force)Test typeIndenter indentation test (without an preliminary test force)Indentation depth setting test, continuous indenter indentation test, repeatedindenter indentation testUS-1001K-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!