Coolant Temperature Sensor AlarmThe coolant temperature sensor alarm is displayedwith the description WT SENSOR or AL11. This alarmisgenerated if the coolant temperature sensor is open orshorted.Compressor Discharge Temperature AlarmThe compressor discharge temperature alarm isdisplayed with the description HIGH CDT or AL12. Thisalarm is generated if the temperature is sensed above155_C (310_F) for three minutes. If the dischargetemperature exceeds 177_C (350_ F), the three minutetimer is overridden and the unit shut down immediately.The fault light (FL) is turned on.Compressor Discharge Temperature Sensor AlarmThe compressor discharge temperature sensor alarmis displayed with the description CD SENSOR or AL13.This alarm is generated if the sensor is open or shorted.Standby Motor Overload AlarmThe standby motor overload alarm is displayed withthe description SBY MOTOR or AL14. This alarm isgenerated when the MOL input is sensed open with theRun Relay energized in electric mode (Diesel/ElectricRelay energized).Fuse AlarmThe fuse alarm is displayed with the descriptionFUSE BAD or AL15. This alarm is generated when theFUSE input is sensed low. The fault light (FL) is turnedon.Compartment 3 Return Air Sensor AlarmThe Compartment 3 return air sensor alarm isdisplayed with the description 3RA SENSOR or AL16.This alarm is generated if the return air sensor is open orshorted. The fault light (FL) is turned on because there isno controlling probe.Display AlarmWhen no communications exist between the mainboard and the display board for eight seconds, the displayalarm description is DISPLAY or AL17Maintenance Hour Meter 1 AlarmThe Maintenance Hour Meter Alarm 1 is displayedwith the description SERVICE 1 or AL18. This alarm isgenerated when the designated hour meter is greaterthan maintenance hour meter 1.Maintenance Hour Meter 2 AlarmThe Maintenance Hour Meter Alarm 2 is displayedwith the description SERVICE 2 or AL19. This alarm isgenerated when the designated hour meter is greaterthan maintenance hour meter 2.Compartment 1 Out-of-Range AlarmThe out-of-range alarm is displayed with thedescription 1RA OUT or AL20. This alarm is generatedwhen compartment 1 is out-of-range (refer to section1.8.6). The fault light (FL) is turned on.Compartment 2 Out-of-range AlarmThe out-of-range alarm is displayed with thedescription 2RA OUT or AL21. This alarm is generatedwhen Compartment 2 is out-of-range (refer to section1.8.6). The fault light (FL) is turned on.Compartment 3 Out-of-range AlarmThe out-of-range alarm is displayed with thedescription 3RA OUT or AL22. This alarm is generatedwhen Compartment 3 is out-of-range (refer to section1.8.6). The fault light (FL) is turned on.No Power for Standby Alarm (<strong>Truck</strong> <strong>Unit</strong>)“NO POWER” will be displayed if truck unit isswitched to standby and power plug is not plugged in.62-028841-22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!