4.22 CONFIGURATION OF MICROPROCESSORWhen replacing a microprocessor it is important tocheck that the configurations are compatible for the unitinto which it will be installed. (This same board fits bothtrailer and truck model units.) All configuration fieldsshould be viewed before starting the unit.To reach the configuration fields:1. Turn the Run/Stop switch to the Stop position.2a. <strong>Trailer</strong> units only --- With the unit off, locate theserial port plug located below the control panel. Removethe protective plug to gain access to the wire terminals.Place an insulated jumper wire between wires SPA andSPB at the serial port plug.2b. <strong>Truck</strong> units only ---Place an insulated jumperwire between plug terminals L (SPA) and M (SPB) in the“CC” plug (see plug drawing below for terminallocations.)CAUTIONDo not allow jumper wire to touch anyground.3. Turn the Run/Stop switch to the Run position.TheFAULTlightwillcomeon,andthemicrodisplaywillread “CNF1 TV” or “CNF1 DI”. Remove the jumperwire from the serial port and reinstall the protective plug.The configuration screen will now remain available for 5minute. Scroll through the configuration list using theFunction Key and compare the settings with those shownon the table in the next column. If any of theconfigurations need to be changed, continue with step (4)below.4. To change the configuration selection:a. Bring the configuration to be changed onto thedisplay. Press the Enter Key to allow change access to thedisplayed configuration.b. Press either the Up or Down Keys to displayavailable selections for that configuration. Leave thecorrect selection on the screen. The selection display willflash, warning the operator that the displayed value hasnot been entered. Press the Enter Key to enter the newselection into memory. (The display will revert to theoriginal selection if no further action is taken for the nextfive seconds.)c. Continue to scroll through the configuration listby pressing the Function Key. Change any otherconfigurations as required.d. When finished turn the Run/Stop switch to theStop position, then back to the Run position to start theunit.ConfigurationCNF1OFFONCNF2OFFONCNF3OFFONCNF4OFFONDescriptionDI EngineTV EngineCDT not usedCDT used86_ Setpoint90_ SetpointCNF5 --- Not UsedCNF6CNF7CNF8CNF9OFFONOFFONOFFONOFFONHeat lockout on +10_FHeat lockout off (<strong>Truck</strong> units)<strong>Trailer</strong> unit<strong>Truck</strong> unitHigh speed start (<strong>Truck</strong> unit)Low speed start (<strong>Trailer</strong> unit)Belt driven fansElectric fan motorsCNF10 --- Not UsedCNF11OFFONOut-of-range alarmOut-of-range alarm and unit shut downFunctions normalFunctions lockedCNF12 --- Not UsedCNF13 --- Not UsedCNF14 --- Not UsedCNF15 --- Not UsedCNF16OFFONAlt aux alarm onlyAlt aux alarm shut unit down62-028844-20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!