<strong>VISION</strong> <strong>TOUCH</strong> <strong>THR</strong>Ventilation8.3.3The parameters of the Ventilation menu allow to set the management of the fans in thevarious operating modes. The “Ventilation” menu can be accessed from the mainConfiguration page (“Parameters” Button). The display of this item can be set in the“Password” sub-menu => “Configure user level menu” and by selecting the “Ventilation”item (installer login required).FansVARIABLES MEANING VALUES DEFAULTF5F3F4F6F7F8EFaFsFstFan pause after defrost (minutes)Allows to keep the fans stopped for a time F5 after dripping.This time starts counting from the end of dripping. If drippingis not set, at the end of defrost the fans pause immediately.Fan status when cold, hot, humidification anddehumidification are stoppedFan pause during defrostEvaporator fans activation for air circulation.The fans are activated for a time defined by F7 if they werenot switched on for the time F6.If the time of activation coincides with the defrost phase, itwaits for the end of defrost.The fan speed (high/low) is the same as that selected for thephase in progress.Evaporator fans activation period for air circulation.Time fans running for air circulation (F6).Fan speed in seasoning/preservation phase. The value ofthis variable changes based on the setting made in the lastphase of a program carried out.Enables 0-10V output for fan speed controlThe digital outputs high and low fan speed becomes theenable. (Them Turned on if the 0-10V output higher than 0V)Fan speed (percentage) when EFa=1.The value of this variable changes based on the setting madein the last phase of a program carried out.FAN blocking TEMPERATUREThe fans do not switch on if the value of the temperature readby the evaporator probe is higher than the value of thisparameter. The block is deactivated when the evaporatorprobe is disabled or presents an error.0 ÷ 10 min 0 min0 = Fans runningconstantly1 = Fans off if cold,hot, humidificationand dehumidificationoff2 = off with coldactive0 = Fans runningduring defrost1 = Fans not runningduring defrostOFF / 1 ÷ 240 min11OFF0 ÷ 240 sec 10 sec0 = High speed1 = Low speed0 = disabled1 = enabled20 ÷ 100 % 100%-45 ÷ 99 °C +99°CFd Differential for Fst 1…+10°C 2°C00Pag. 49 USER AND MAINTENANCE MANUAL Rev. 01-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!