12.07.2015 Views

VISION TOUCH THR

VISION TOUCH THR

VISION TOUCH THR

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>VISION</strong> <strong>TOUCH</strong> <strong>THR</strong>Recoveries (Pause)8.3.6The refreshment is a phase of the pause process of the temperature and humiditymanagement. Refreshments are managed with parameters Pr and dr.Pr defines the interval between one refreshment and the following one, dr defines theduration of the refreshment. It is possible, at any time, to force an air change with the“Pause” button. To interrupt a recovery press and hold the “Recoveries” key. The“Recoveries” menu can be accessed from the main Configuration page (“Parameters”Button). The display of this item can be set in the “Password” sub-menu => “Configureuser level menu” and by selecting the “Recoveries” item (installer login required).PauseVARIABLES MEANING VALUES DEFAULTPrRecovery period.Interval between one recovery and the next. Recovery is a workpause in which cold, hot, humidification and dehumidificationare disabledConfigure <strong>THR</strong>OFF / 00:01 ÷24:00dr Recovery phase period. 1 ÷ 240 min 120 min“Configure <strong>THR</strong>” allows to select which functions of the <strong>THR</strong> control unit are enabled; inparticolare consente di abilitare/disabilitare la gestione dell’umidità e del caldo.The “Configure <strong>THR</strong>” menu can be accessed from the main Configuration page(“Parameters” Button). The display of this item can be set in the “Password” sub-menu =>“Configure user level menu” and by selecting the “Configure <strong>THR</strong>” item (installer loginrequired).OFF8.3.7Configure <strong>THR</strong>VARIABLES MEANING VALUES DEFAULTdEUEnUEndEnHHrDehumidification mode selection.Separate dehumidification calls hot andcold only for temperature.Humidification enablingDehumidification enablingHot enablingHumidity management0 = cooling1= heating2= separate dehumidification3= separate dehumidification andactive when cold output is off0 = disabled1 = enabled0 = disabled1 = enabled0 = hot disabled1 = hot enabledHr = 0 humidity managementdisabled.The humidity probe can beconnected without error on thedisplay.Hr = 1 humidity management enabled.01111Pag. 51 USER AND MAINTENANCE MANUAL Rev. 01-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!