Example #4: What are the device’s settings for all Codabar selections?Enter: cbr?.Response: CBRENA1[ACK],SSX0[ACK],CK20[ACK],CCT1[ACK],MIN2[ACK],MAX60[ACK],DFT[ACK].This response indicates that the device’s Codabar Coding Enable (CBRENA) isset to 1, or on;the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;the Check Character (CK2) is set to 0, or Not Required;concatenation (CCT) is set to 1, or Enabled;the Minimum Message Length (MIN) is set to 2 characters;the Maximum Message Length (MAX) is set to 60 characters;and the Default setting (DFT) has no value.Trigger CommandsYou can activate and deactivate the scanner with serial trigger commands.First, the scanner must be put in Manual/Serial Trigger Mode either by scanningthe Manual/Serial Trigger Mode bar code (page 3-4), or by sending the Manual/Serial Menu Command (page 10-11). Once the scanner is in serial triggermode, the trigger is activated and deactivated by sending the following commands:Activate:SYN T CRDeactivate:SYN U CRThe scanner scans until a bar code has been read, until the deactivate commandis sent, or until the serial time-out has been reached (see Read Time-Out(Serial Trigger Mode) on page 3-4 for a description, and the serial command onpage 10-11).10 - 4 2020/<strong>3820</strong> User’s Guide