Model NomenclaturePrecedent PackagedCoolingR-410AT S C 036 E 3 R B A ** C 0 0 0 A 1 0 0 0 1 A 11 2 3 4,5,6 7 8 9 10 11 12,13 14 15 16 17 18 19 20 21 22 23 24 25DIGIT 1 - Unit FunctionT = DX CoolingY = DX Cooling, Gas HeatX = Packaged Heat pump24DIGIT 2 - EfficiencyS = Standard Efficiency (13 SEER R-410A)H = High Efficiency (15 SEER R-410A)DIGIT 3 -AirflowC = ConvertibleDIGITS 4,5,6 - Nominal Gross CoolingCapacity (MBh)036 = 3 Ton 090 = 7½ Ton, Single Compressor046 = 4 Ton 092 = 7½ Ton, Dual Compressor060 = 5 Ton 102 = 8½ Ton072 = 6 Ton 120 = 10 TonDIGIT 7 - Major Design SequenceE = R-410A RefrigerantDIGIT 8 - Unit Voltage1 = 208-230/1/603 = 208-230/3/604 = 460/3/60W = 575/3/60DIGIT 9 - Unit ControlsE = Electromechanical1R = ReliaTel MicroprocessorDIGIT 10 - Heating CapacityNote: (Applicable to Digit 1, W models only)0 = No Electric HeatA = 5 kW (1 phase)2B = 6 kW (3 phase)D = 10 kW (1 phase)2E = 12 kW (3 phase)F = 14 kW (1 phase)2G = 18 kW (1&3phase)J = 23 kW (3 phase)Note: Applicable to Digit 1, Y models only.L = LowM = MediumH = HighX = Low, Stainless Steel Heat ExchangerY = Medium, Stainless Steel Heat ExchangerZ = High, Stainless Steel Heat ExchangerDIGIT 11 - Minor Design SequenceA = First SequenceDIGITS 12, 13 - Service Sequence** = Factory AssignedDIGIT 14 - Fresh Air Selection0 = No Fresh AirA = Manual Outside Air Damper 0-50%5B = Motorized Outside Air Damper 0-50%C = Economizer, Dry Bulb 0-100%without Barometric Relief8D = Economizer, Dry Bulb 0-100%with Barometric Relief8E = Economizer, Reference Enthalpy0-100% without Barometric Relief48F = Economizer, Reference Enthalpy0-100% with Barometric Relief48G = Economizer, Comparative Enthalpy0-100% without Barometric Relief48H = Economizer, Comparative Enthalpy0-100% with Barometric Relief48DIGIT 15 - Supply Fan/Drive Type/Motor0 = Standard Drive7Z = Optional Belt Drive MotorpDIGIT 16 - Hinged Service Access/Filters0 = Standard Panels/Standard FiltersA = Hinged Access Panels/Standard FiltersB = Standard Panels/2” Pleated FiltersC = Hinged Access Panels/2” Pleated FiltersDIGIT 17 - Condenser Coil Protection0 = Standard Coil1 = Standard Coil with Hail Guard2 = Epoxy Pre-Coated Condenser Coil3 = Epoxy Pre-Coated Condenser Coil with Hail Guard4 = CompleteCoat Condenser Coil5 = CompleteCoat Condenser Coil with Hail GuardDIGIT 18 - Through the Base ProvisionsNote: (Applicable to Digit 1, T models only)0 = No Through the Base ProvisionsA = Through the Base Electric9Note: (Applicable to Digit 1, Y models only)B = Through the Base Gas PipingC = Through the Base Electric and Gas PipinguDIGIT 19 - Disconnect/Circuit Breaker/Phase Monitor (3 phase only)0 = No Disconnect/No Circuit Breaker/No Phase Monitora1 = Unit Mounted Non-Fused Disconnect92 = Unit Mounted Circuit Breaker93 = Phase Monitoras4 = Phase Monitor & Non-Fused DisconnectSwitch9as5 = Phase Monitor & Circuit Breaker9asDIGIT 20 - Convenience Outlet0 = No Convenience OutletA = Unpowered Convenience OutletB = Powered Convenience Outlet (3 phase only)0DIGIT 21 - Communications Options40 = No Communications Interface1 = <strong>Trane</strong> Communications Interface2 = LonTalk ® Communications Interface3 = Novar 2024 Controls14 = Novar 3051 Controls1DIGIT 22 - Refrigeration System Option0 = Standard Refrigeration CoileDIGIT 23 - Refrigeration ControlsNote: (Applicable to Digit 7 = E)0 = No Refrigeration Control61 = Frostatw2 = Crankcase Heater33 = Frostatw and Crankcase Heater3DIGIT 24 - Smoke Detectori0 = No Smoke DetectorA = Return Air Smoke DetectorerB = Supply Air Smoke DetectorC = Supply and Return Air Smoke DetectorserDIGIT 25 - Monitoring Controls40 = No Monitoring Controlt1 = Clogged Filter Switcht2 = Fan Failure Switchu3 = Discharge Air Sensing Tubet4 = Clogged Filter Switch and Fan Fail Switcht5 = Clogged Filter Switch and DischargeAir Sensing Tubet6 = Fan Fail Switch and Discharge AirSensing Tubet7 = Clogged Filter and Fan Fail Switchesand Discharge Air Sensing Tubet8 = Novar Return Air SensoryModel Number Notes1 Not available for 3-5 tons, R-410A Heat Pumps.2 Available on 3-5 Standard Efficiency.3 Standard on all 15 SEER and 4-5Ton E3, 4, W Heat Pumpsand all 6-10 Ton units.4 Not available with electromechanical controls.5 Manual outside air damper will ship factory supplied withinthe unit, but must be field installed.6 High pressure control is standard on all units.7 Multispeed direct drive standard on single-phase and 15SEER products. Belt drive standard on three-phase 13SEER and 6-10 Ton products.8 Economizer with Barometric Relief is for downflowconfigured units only. Order Economizer without BarometricRelief for horizontal configuration. Barometric Relieffor horizontal configured units must be ordered as fieldinstalled accessory.9 Through the base electric required when ordering disconnect/circuitbreaker options.0 Requires use of Disconnect or Circuit Breaker.q Standard metering devices are TXVs.w Frostat cannot be field installed in electro-mechanical units.e The return air smoke detector may not fit up or workproperly on the Precedent units when used in conjunctionwith 3rd party accessories such as bolt on heat wheels,economizers and power exhaust. Do not order the returnair smoke detectors when using this type of accessory.r Return Air Smoke Detector cannot be ordered with NovarControls.t These options are standard when ordering Novar Controls.y This option is used when ordering Novar Controls.u Includes gas piping and shutoff (field assembly required).i Not available with high temperature duct sensor accessory.o Requires hinged access panels.p Belt Drive optional on three phase 15 SEER, R-410A units.a Phase Reversal protection is standard on 3-5 ton units withDirect Drive and 3 phase power.s Available on Belt Drive (3-10) tonsExample:Model number TSC036E3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/3/60 power supply, ReliaTel controls, 6 kW electricheater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels/filters, standard condenser coil with no coil protection, through the base electric, non-fuseddisconnect, no convenience outlet or communications interface, standard refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.© <strong>Trane</strong> 2007PC – 37 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!