2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Model NomenclaturePrecedent Convertible Pkg.Gas/ElectricY S C 036 A 3 R B A ** C 0 0 0 A 1 0 0 0 1 A 11 2 3 4,5,6 7 8 9 10 11 12,13 14 15 16 17 18 19 20 21 22 23 24 25DIGIT 1 - Unit FunctionT = DX CoolingY = DX Cooling, Gas HeatDIGIT 2 - EfficiencyS = Standard EfficiencyH = High EfficiencyDIGIT 3 - AirflowC = ConvertibleDIGITS 4,5,6 - Nominal Gross CoolingCapacity (MBh)033/036 = 3 Ton043/048 = 4 Ton060/063 = 5 Ton072 = 6 Ton090 = 7.5 Ton, Single Compressor092 = 7.5 Ton, Dual Compressors102 = 8.5 Ton120 = 10 TonDIGIT 7 - Major Design SequenceA = R-22 RefrigerantDIGIT 8 - Unit Voltage3 = 208-230/3/604 = 460/3/60W = 575/3/60K = 380/3/60DIGIT 9 - Unit ControlsE = ElectromechanicalR = ReliaTel MicroprocessorDIGIT 10 - Heating CapacityNote: Sequence may be any letter A throughZ, or any digit 1 through 9.0 = No Electric HeaterB = 6 kw (3 phase)C = 9 kw (3 phase)E = 12 kw (3 phase)G = 18 kw (3 phase)J = 23 kw (3 phase)K = 27 kw (3 phase)N = 36 kw (3 phase)P = 54 kw (3 phase)Note: Applicable to Digit 1, Y models only.L = LowM = MediumH = HighX = Low, Stainless Steel Heat ExchangerY = Medium, Stainless Steel Heat ExchangerZ = High, Stainless Steel Heat ExchangerDIGIT 11 - Minor Design SequenceA = First SequenceDIGIT 12,13 - Service Sequence** = Factory Assigned© <strong>Trane</strong> 2007DIGIT 14 - Fresh Air Selection0 = No Fresh AirA = Manual Outside Air Damper 0-50%eB = Motorized Outside Air Damper 0-50%C = Economizer, Dry Bulb 0-100% without BarometricRelief2D = Economizer, Dry Bulb 0-100% with BarometricRelief2E = Economizer, Reference Enthalpy0-100% without Barometric Relief12F = Economizer, Reference Enthalpy0-100% with Barometric Relief12G = Economizer, Comparative Enthalpy0-100% without Barometric Relief12H = Economizer, Comparative Enthalpy0-100% with Barometric Relief12DIGIT 15 - Supply Fan/Drive Type/Motor0 = Standard Driveu1 = Oversized Motor2 = Optional Belt Drive MotoroDIGIT 16 - Hinged Service Access & Filters0 = Standard Panels & Standard FiltersA = Hinged Access Panels & StandardFiltersB = Standard Panels & 2" Pleated FiltersC = Hinged Access Panels & 2" PleatedFiltersDIGIT 17 - Condenser Coil Protection0 = Standard Coil1 = Standard Coil with Hail guard2 = Black Epoxy Pre-Coated Condenser Coil3 = Black Epoxy Pre-Coated Condenser Coil with HailGuard4 = CompleteCoat Condenser Coil5 = CompleteCoat Condenser Coil with Hail GuardDIGIT 18 - Through the Base Provisions ModelsNote: (Applicable to Digit 1, T or Y models)0 = No Through the Base ProvisionsA = Through the Base ElectrictNote: (Applicable to Digit 1, Y models only)B = Through the Base Gas PipingC = Through the Base Electric and Gas PipingwDIGIT 19 - Disconnect/Circuit Breaker/Phase Monitor (3 phase only)0 = No Disconnect or Circuit Breaker/No Phase Monitorp1 = Unit Mounted Non-Fused Disconnectt2 = Unit Mounted Circuit Breakert3 = Phase Monitora4 = Phase Monitor & Non-Fused Disconnect Switch5 = Phase Monitor & Circuit BreakerDIGIT 20 - Convenience Outlet0 = No Convenience OutletA = Unpowered Convenience OutletB = Powered Convenience Outlet (3 phase only)3DIGIT 21 - Communications Options10 = No Communications Interface1 = <strong>Trane</strong> Communications Intertace2 = LonTalk ® Communications Interface3 = Novar 2024 Controls4 = Novar 3051 ControlsDIGIT 22 - Refrigeration System Option0 = Standard Refrigeration System4A = Thermal Expansion Valve (TXV)B = Dehumidification (Hot Gas Reheat Coil)riDIGIT 23 - Refrigeration Controls0 = No Refrigeration Control1 = High Pressure Control162 = Frostat53 = Crankcase Heatery4 = High Pressure Control16 and Frostat55 = High Pressure Control16 and Crankcase Heatery6 = Frostat5 and Crankcase Heater6y7 = High Pressure Control,16 Frostat5 andCrankcase Heater6yDIGIT 24 - Smoke Detector0 = No Smoke DetectorA = Return Air Smoke Detector89B = Supply Air Smoke DetectorC = Supply and Return Air Smoke Detectors9DIGIT 25 - Monitoring Controls10 = No Monitoring Control01 = Clogged Filter Switch02 = Fan Failure Switch03 = Discharge Air Sensing Tube04 = Clogged Filter Switch and Fan Fail Switch05 = Clogged Filter Switch and Discharge Air SensingTube06 = Fan Fail Switch and Discharge Air Sensing Tube07 = Clogged Filter and Fan Fail Switches and DischargeAir Sensing Tube08 = Novar Return Air SensorqModel Number Notes1 Not available with electromechanical unit controls.2 Economizer with Barometric Relief is for downflow configured unitsonly. Order Economizer without Barometric Relief for horizontalconfiguration. Barometric Relief for horizontal configured unitsmust be ordered as field installed accessory.3 Requires use of Disconnect or Circuit Breaker.4 Standard refrigeration metering device – short orifice.5 Frostat cannot be field installed in electro-mechanical units.6 High Pressure control is standard on 3-phase units with scrollcompressors and in 3 ton standard efficiency units.7 Not available with High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properlyon the Precedent units when used in conjunction with 3rd partyaccessories such as bolt on heat wheels, economizers and powerexhaust. Do not order the return air smoke detectors when usingthis type of accessory.9 Return Air Smoke Detector cannot be ordered with Novar Controls.0 These options are standard when ordering Novar Controls.q This option is used when ordering Novar Controls.w Includes gas piping and shutoff (field assembly required).e The manual outside air damper will ship factory supplied within theunit, but must be field installed.r Requires selection of 2” Pleated Filters (option B or C) for Digit 16.t Through the base electric required when ordering disconnect/circuit breaker options.y Crankcase heaters are standard on 3 ton standard efficiency and7.5 ton single compressor units.u Direct Drive (3-5 tons); Belt Drive (6-10 tons)i Not available on 6 ton units and all single phase or standardefficiency.o Belt drive standard on 13 SEER, R-22 products.p Phase Monitor Standard on 3-5 ton Direct Drive Indoor Motor.a Available on 3-10 ton Belt Drive Indoor Motors.PG – 14 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!