12.07.2015 Views

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Model NomenclaturePrecedent Convertible Pkg.Gas/ElectricY H C 033 A 3 R L A ** C 0 0 0 C 1 0 0 0 1 A 11 2 3 4,5,6 7 8 9 10 11 12,13 14 15 16 17 18 19 20 21 22 23 24 25DIGIT 1 - Unit FunctionY = DX Cooling, Gas HeatDIGIT 2 - EfficiencyH = High EfficiencyDIGIT 3 - AirflowC = ConvertibleDIGITS 4,5,6 - Nominal Gross CoolingCapacity (MBh)033 = 3 Ton043 = 4 Ton063 = 5 TonDIGIT 7 - Major Design SequenceA = R-22 RefrigerantDIGIT 8 - Unit Voltage3 = 208-230/3/604 = 460/3/60W = 575/3/60DIGIT 9 - Unit ControlsE = Electro-<strong>Mechanical</strong>R = ReliaTelMicro-processorDIGIT 10 - Heating CapacityL = LowM = MediumH = HighX = Low, Stainless Steel Heat ExchangerY = Medium, Stainless Steel Heat ExchangerZ = High, Stainless Steel Heat ExchangerDIGIT 11 - Minor Design SequenceA = First SequenceDIGIT 12,13 - Service Sequence** = Factory AssignedDIGIT 14 - Fresh Air Selection0 = No Fresh AirA = Manual Outside Air Damper 0-50%B = Motorized Outside Air Damper 0-50%C = Economizer, Dry Bulb 0-100% without BarometricReliefD = Economizer, Dry Bulb 0-100% with BarometricReliefE = Economizer, Reference Enthalpy0-100% without Barometric ReliefF = Economizer, Reference Enthalpy0-100% with Barometric ReliefG = Economizer, Comparative Enthalpy0-100% without Barometric ReliefH = Economizer, Comparative Enthalpy0-100% with Barometric ReliefDIGIT 15 - Supply Fan/Drive Type/Motor0 = Standard Belt DriveDIGIT 16 - Hinged Service Access & Filters0 = Standard Panels & FiltersA = Hinged Access Panels & Standard FiltersB = Standard Panels & 2" Pleated FiltersC = Hinged Access Panels & 2" Pleated FiltersDIGIT 17 - Condenser Coil Protection0 = Standard Coil1 = Standard Coil with Hail Guard2 = Epoxy Pre-Coated Condenser Coil3 = Epoxy Pre-Coated Condenser Coil with Hail Guard4 = CompleteCoat Condenser Coil5 = CompleteCoat Condenser Coil with Hail GuardDIGIT 18 - Through the Base Provisions0 = No Through the Base ProvisionsA = Through the Base ElectricB = Through the Base Gas PipingC = Through the Base Electric and Gas PipingDIGIT 19 - Disconnect/Circuit BreakerPhase Monitor (3 phase only)0 = No Disconnect, Circuit Breaker or Phase Monitor1 = Unit Mounted Non-Fused Disconnect2 = Unit Mounted Circuit Breaker3 = Phase Monitor4 = Phase Monitor and Non-Fused Disconnect Switch5 = Phase Monitor and Circuit BreakerDIGIT 20 - Convenience Outlet0 = No Convenience OutletA = Unpowered Convenience OutletB = Powered Convenience Outlet (3 phase only)DIGIT 21 - Communications Options0 = No Communications Interface1 = <strong>Trane</strong> Communications Interface2 = LonTalk ® Communications Interface3 = Novar 2024 Controls4 = Novar 3051 ControlsDIGIT 22 - Refrigeration System Option0 = Standard Refrigeration CoilB = Dehumidification (Hot Gas Reheat Coil)DIGIT 23 - Refrigeration Controls0 = No Refrigeration Control1 = High Pressure Control2 = Frostat3 = Crankcase Heater4 = High Pressure Control and Frostat5 = High Pressure Control and Crankcase Heater6 = Frostat and Crankcase Heater7 = High Pressure Control, Frostat andCrankcase HeaterDIGIT 24 - Smoke Detector0 = No Smoke DetectorA = Return Air Smoke DetectorB = Supply Air Smoke DetectorC = Supply and Return Air Smoke DetectorsDIGIT 25 - Monitoring Controls0 = No Monitoring Control1 = Clogged Filter Switch2 = Fan Failure Switch3 = Discharge Air Sensing Tube4 = Clogged Filter Switch and Fan Fail Switch5 = Clogged Filter Switch and Discharge Air SensingTube6 = Fan Fail Switch and Discharge Air Sensing Tube7 = Clogged Filter and Fan Fail Switchesand Discharge Air Sensing Tube8 = Novar Return Air SensorExample:Model number YHC033A3RLA**C000C10001A10 describes a unit with the following characteristics: DX Cooling with natural gas heating, 3 ton nominal cooling capacity,208-230/3/60 power supply, ReliaTel controls, low heat model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels,standard condenser coil with no coil protection, through the base electric and gas access, non-fused disconnect, no convenience outlet or communications interface, standardrefrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.© <strong>Trane</strong> 2007PG – 27 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!