Model NomenclatureVoyager R-410AY C D 150 E 3 0 0 A A1 2 3 456 7 8 9 10 11 12Digit 1,2 — Unit TypeTC = Packaged Cooling, Electric HeatTF = With Factory Installed OptionsYC = Packaged Gas/ElectricYF = With Factory Installed OptionsDigit 3 — Airflow ConfigurationD = DownflowH = HorizontalDigit 4,5,6 — Nominal Gross Cooling Capacity(MBh)150 = 12½ Tons Standard Efficiency180 = 15 Tons Standard Efficiency210 = 17½ Tons Standard Efficiency240 = 20 Tons Standard Efficiency300 = 25 Tons Standard EfficiencyDigit 7 — Major Design SequenceDigit 8 — Voltage Selection3 = 208-230/3/604 = 460/3/60W = 575/3/60Digit 9,10 — Factory Installed OptionsNote: (Applicable to Digit 1, 2 T models only)00 = No Factory-Installed Options0A = Factory-Installed Economizer0B = Oversized Motor0C = Downflow Economizer and Oversized Motor0F = <strong>Trane</strong> Communications Interface (TCI)0G = Downflow Economizer and TCIDigit 9 — Heating CapacityNote: (Applicable to Digit 1, 2 Y models only)L = Low HeatH = High HeatV = Modulating Gas HeatDigit 10 — Factory Installed OptionseNote: (Applicable to Digit 1, 2 Y models only)0 = Packed Stock, No OptionsA = Downflow Economizer1B = Oversized Motor5C = Downflow Economizer and Oversized Motor1F = <strong>Trane</strong> Communications Interface (TCI)5tG = Downflow Economizer & TCI12Digit 11 — Minor Design SequenceDigit 12 — Service SequenceNote: Explanation of Model Number Notes located onthis page.Note: Most Factory Installed Options (FIOPS) availablefor Downflow Air Discharge units only. Pleaseverify with ordering system for availability.Options*Factory Installed Optionse• 2" Pleated Filters5• Black Epoxy Pre-Coated Coils5• Differential Pressure Switches• High Efficiency Motors5• Hinged Access Doors• Novar Return Air Sensorw• Novar Unit Controlsr• Powered or Unpowered Convenience Outlet4• Stainless Steel Heat Exchanger with 10-yearwarranty5• Supply and/or Return Air Smoke Detector9• Through the Base Electrical Access• Through the Base Electrical with CircuitBreaker0q• Through the Base Electrical with DisconnectSwitch60qFactory* or Field Installed Optionse• Barometric Relief• Clogged Filter/Fan Failure Switch25• Discharge Air Sensing Kit25• Economizer (Downflow)1• Electric Heaters57q• LonTalk ® Communications Interface (LCI)5• Oversized Motors5• Reference or Comparative35 Enthalpy• Tool-less Hail Guards5• <strong>Trane</strong> Communications Interface (TCI)5tField Installed Options• CO 2 Sensing• Digital Display Zone Sensor• Dual Thermistor Remote Zone Sensor• Economizer (Horizontal)• High Altitude Kit• High and Low Static Drive Kits• Humidity Sensor• Low Static Drive• LP Conversion Kit• Manual Outside Air Damper• Motorized Outside Air Dampers• Powered Exhaust• Quick Start Kit• ReliaTel Options Module8• Remote Potentiometer• Roof Curb (Downflow Only)• Thermostat• Ventilation Override Accessory2• Zone Sensors and Remote Zone SensorsModel Number Notes1 Some field set up required.2 Requires ReliaTel options module.3 Requires Economizer.4 Must be ordered with Through-the-Base Electrical option orHorizontal-Side Access and either Unit Mounted Disconnect orCircuit Breaker.5 Available factory installed on downflow AND horizontal units.Verify with ordering system.6 Cannot be fused.7 Must be factory installed when using Through-the-Base Options.8 ReliaTel Options Module is required when ordering thefollowing accessories: Clogged Filter Switch, Fan Fail Switch,Discharge Air Sensing Kit, Frostat, Ventilation Override, SmokeDetector, Dehumidification and Modulating Gas Heat Furnace.9 Option cannot be ordered in conjunction with field installedeconomizer. Must be factory installed. The return air smokedetector may not fit up or work properly on the Voyager unitswhen used in conjunction with 3rd party accessories (such asbolt on heat wheels, economizers, and power exhaust). Do notorder the return air smoke detectors when using this type ofaccessory.0 Unit mounted disconnect and circuit breakers are mutuallyexclusive of each other.q Through-the-base electrical option or Horizontal-Side Accessmust be ordered with either unit mounted disconnect or circuitbreaker. When adding heat, must order <strong>Trane</strong> Electric Heat.w This option consists of the Novar return air sensor (Novar#WTS-10) that is wired and shipped in the return air section ofthe unit. The sensor ships with approximately 15' of extra wirefor dropping down the return air duct (downflow only).e All Factory Installed Options are Built-to-Order. Check orderservices for estimated production cycle.r The Novar control option includes the following factory installedand wired devices: Novar ETM-2024 or Novar 3051 rooftop controller,fan proving switch, clogged filter or unit shutdown switch,Cool 1, Cool 2, Heat switch and discharge air sensor (downflowonly).Note: Option cannot be ordered in conjunction with FIOPS SmokeDetector option.t TCI is for use with non-VariTrac systems and VariTrac systems.Note: *Most Factory Installed Options (FIOPS) available for DownflowAir Discharge units only. Please verify with orderingsystem for availability.© <strong>Trane</strong> 2007PG – 64 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!