Horizontal/DownflowPackaged Gas/ElectricFactory Installed Options (FIOPS)Accessories:ModelNumber Description Used WithSwitchesFIYDFPS005A Clogged Filter Switch All Voyager Units w/FIYABRD002BFIYDFPS006A Fan Failure Switch All Voyager Units w/FIYABRD002BEconomizer Actuator Logic ModuleEconomizer Actuator Logic Module is required with FIOPS (Factory Installed Options) Enthalpy and Novar Controls.FIYLGCM001A Economizer Actuator Logic Module All Voyager 12½-25 Tons with EconomizerEnthalpy KitsMust select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected whenordering the field installed accessory.FIYENTH007A Reference Enthalpy Downflow Units w/A,C or G in 10th DigitFIYENTH008A Comparative Enthalpy Downflow Units w/A,C or G in 10th DigitTCIFIYICSI004B <strong>Trane</strong> Communication Interface YC*150-301LCIFIYLTCI003B LonTalk ® Interface YC*150-301Discharge Air Sensing KitUsed for true discharge air sensing in heating models. Functional only with ReliaTel Options Module (FIYABRD002B).FIYTUBE008A Discharge Air Sensing Kit YCD150-301 w/FIYABRD002BFIYTUBE009A Discharge Air Sensing Kit YCH150-301 w/FIYABRD002BTool-less Condenser Hail GuardFIYGARD001B Tool-less Condenser Hail Guard YC*150DFIYGARD002B Tool-less Condenser Hail Guard YC*151C,180B,210CFIYGARD003A Tool-less Condenser Hail Guard YC*181C,211C,241C,301C,240BFIYGARD005A Tool-less Condenser Hail Guard YC*300BNovar ControlsThe Novar control option includes the following factory installed and wired devices: Novar ETM-2024 rooftop controller, fan proving switch, clogged filter or unitshutdown switch, Cool 1,Cool 2, Heat switch and discharge air sensor (Novar# DTS-30,20-170°F) (Downflow only). NOTE: Option cannot be ordered in conjunctionwith Factory Installed Smoke Detector option. Must select Economizer Actuator Logic Module (FIYLGCM001A) in order to configure and price a Voyager unit. Thismodule does not need to be selected when ordering the field installed accessory. Novar Controls with an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) willalso be required to select the Economizer Actuator Logic Module.FIYCNTL013A Novar Control, 208-230V YCD150-301*3FIYCNTL015A Novar Control, 460 & 575 V YCD150-301*4,WNovar Return Air SensorThis option consists of the Novar return air sensor (Novar # WTS-10) that is wired and shipped in the return air section of the unit. The sensor ships withapproximately 15' of extra wire for dropping down the return air duct (downflow only).FIYNRAS001A Return Air Sensor FIYCNTL013A and FIYCNTL015A2" Pleated FiltersFIYPLTD001A 2" Pleated Filters YC*150,151,180,210FIYPLTD002A 2" Pleated Filters YCD181,211,240,241,300,301FIYPLTD003A 2" Pleated Filters YCH181,211,240,241,300,301Novar Controls-3051The Novar control option includes the following factory installed and wired devices: Novar 3051 rooftop controller, fan proving switch, clogged filter or unitshutdown switch, and discharge air sensor (Novar # DTS-30, 20-170°F) (downflow only). NOTE: This option can be ordered in conjunction with factory installedSmoke Detector option. It cannot be ordered in conjunction with with economizer, either field or factory installed.Must select Economizer Actuator Logic Module(FIYLGCM001A) in order to configure and price a Voyager unit. This module does not need to be selected when ordering the field installed accessory. Novar Controlswith an economizer in the 10th digit (Digit 10=A,C,G,K,L,N,R) will also be required to select the Economizer Actuator Logic Module.FIYCNTL016A Novar Control, 460 and 575V YC*181,211,240,241,300,301*4,WFIYCNTL017A Novar Control, 208-230V YC*150,151,180,210*3FIYCNTL018A Novar Control, 460 and 575V YC*150,151,180,210*4,WFIYCNTL019A Novar Control, 208-230V YC*181,211,240,241,300,301*3Novar Zone SensorThis option consista of Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.FIYNZSR001A Novar Zone Sensor for Novar 3051 FIYCNTL016A© <strong>Trane</strong> 2007FIOP – 13 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!