12.07.2015 Views

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TUH3B060 — D120AUpflow/Horizontal LeftDirect/Non-Direct Vent-Induced DraftSpecifications:Upflow/Horizontal Left Condensing (Sealed Combustion -1 or 2 Pipe Vent Option)Airflow Capacity (000) UncratedModel In Tons Output-BTUH ICS1 Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 3 Stg 2 Stg 1 AFUE Size H W D Plant WeightTUH3B060ACV3VA 3 57.0 2 23.0 95.0 2" 40 17.5 28 TR 158TUH3B080ACV3VA 3 75.0 2 30.0 95.0 2" 40 17.5 28 TR 168TUH3C100ACV4VA 4 95.0 2 38.0 95.0 3" 40 21.0 28 TR 197TUH3D120ACV5VA 5 114.0 2 52.0 95.0 3" 40 24.5 28 TR 2061 Isolated Combustion System.2 Second stage output capacity is approximately equal to 65% of third stage output capacity. There is no testing protocol for this value.XC95Communicating OnlyVariable SpeedThree-StageGas FurnaceAccessories:Model Mfg. ShippingNumber Description Used With Plant WeightExtended Warranties (See Extended Warranty Section)TCONT900AC43UA5 Communicating Comfort Control All TUH3 Furnaces TR 1BAYLPKT220A Propane Conversion Kit All TUH3 Furnaces TR 1BAYLPSS220A3 Propane Conversion Kit All TUH3 Furnaces TR 1BAYRACK960A4 Filter Rack Kit-Internal All TUH3 Furnaces TR 2BAYFLTR200 Side Filter Rack - External All TUH3 Furnaces TR 5BAYFLTR203 Filter Kit/Horizontal Conversion TUH3B060,080A TR 3BAYFLTR204 Filter Kit/Horizontal Conversion TUH3C100A TR 3BAYFLTR205 Filter Kit/Horizontal Conversion TUH3D120A TR 3BAYFLTR317 Filter Accessory Kit Upflow 17.5" Furnaces TR 2BAYFLTR321 Filter Accessory Kit Upflow 21" Furnaces TR 2BAYFLTR324 Filter Accessory Kit Upflow 24.5" Furnaces TR 2BAYSWT07AHALTA High Altitude Pressure Switch Kit TUH3B060 TR 2BAYSWT08AHALTA High Altitude Pressure Switch Kit TUH3D120 TR 2BAYSWT09AHALTA High Altitude Pressure Switch Kit TUH3B080,C100 TR 2BAYAIR30AVENTA Concentric Vent Kit All TUH3 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TUH3 Furnaces TR 23 With stainless steel burners.4 Left and bottom return only.5 Required for installation of all TUH3 furnaces.Ref: 4/29/08 2:22 pmFeatures:• ComfortLink II Communicating onlyfurnace design• Requires comfort control TCONT900AC43UA• For use with communicating outdoor productsor single stage - cooling only outdoor units• Plug and play installation• Three wire connections to Comfort Control• Variable speed inducer motor• Stored fault code history in microprocessornon-volatile memory• Slide out blower assembly• Variable speed ECM motor with Comfort-R • Silicon Nitride hot surface igniter withadaptive heat up• Direct/Non-Direct vent option• Manual reset flame rollout switches• Power supply 115/1/60• Convertible to Horizontal Left• 3-stage modulating gas valve© <strong>Trane</strong> 2007• PVC venting-1 or 2 pipe option• Accessory hook-up capability• Integrated solid state control withself-diagnostics• Attractive color accents• Heavy gauge aluminized steel heatexchanger• Multi-port In-shot burners• Insulated blower door• Gasketed blower door• Complete front service access• Left/right gas connection• Optional L.P conversion kit• Lifetime limited primary heat exchangeror secondary heat exchanger warranty tooriginal owner (Residential use)• 5-year limited parts warranty• Optional extended warrantiesFU – 25 Effective date: date: January April 28, 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!