12.07.2015 Views

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Accessories:ModelNumber Description Used WithThrough The Base Gas PipingFIYTBUG202A1 Through-the-Base Gas Piping YCD150,151 Low & High HeatYCD180-301 Low HeatFIYTBUG203A1 Through-the-Base Gas Piping YCD180-301 High HeatFIYTBUG205A2 Through-the-Base Gas Piping YCD150,151 Low & High HeatYCD180-301 Low HeatFIYTBUG206A2 Through-the-Base Gas Piping YCD180-301 High HeatConvenience OutletMust be ordered with Through-the Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker.FIYCOPO201A Powered, 120v. Convenience Outlet, 230v. YCD150-301*3FIYCOPO202A Powered, 120v. Convenience Outlet, 460v. YCD150-301*3,4FIYCOPO205A Powered, 120v. Convenience Outlet, 575v. YCD150-301*WFIYCOUP201A Unpowered, 115v. Convenience Outlet YCD150-301FIYCOPO301AA Powered, 120V Convenience Outlet, 230V YCH150-300*3FIYCOPO302AA Powered, 120V Convenience Outlet, 460V YCH150-300*4FIYCOPO303AA Powered, 120V Convenience Outlet. 575V YCH150-300*WFIYCOUP301AA Unpowered, 115V Convenience Outlet YCH150-301,180-300EFilter & Control AccessFIYHNGE004B Hinged Filter/Evap. and Comp./Control Access Door YCD150,180,210FIYHNGE005B Hinged Filter/Evap. and Comp./Control Access Door YCD300FIYHNGE008B Hinged Filter/Evap. and Comp./Control Access Door YCD151FIYHNGE009B Hinged FIlter/Evap. and Comp./Control Access Door YCD181,211,240,241,301FIYHNGE200AA Hinged Filter/Evap. and Comp./Control Access Door YCH150,180, 210FIYHNGE201AA Hinged Filter/Evap. and Comp./Control Access Door YCH300FIYHNGE202AA Hinged Filter/Evap. and Comp./Control Access Door YCH151,150EFIYHNGE203AA Hinged Filter/Evap. and Comp./Control Access Door YCH181-301C3,4,W,180-300EDisconnect SwitchMust be used with Through-the Base Electrical option (downflow only). Cannot be fused.FIYUDC4150A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC6100A Unit Mounted Disconnect Switch Consult Matrix SheetsHigh Efficiency MotorsCan be used on downflow or horizontal units unless specified on matrix sheets.FIYHEMT001A 2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) Consult Matrix SheetsFIYHEMT002A 2 HP High Effic. Motor (86.5 Eff. (575/60/3) Consult Matrix SheetsFIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT009A 7½ HP High Effic. Motor (90.2 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT010A 7½ HP High Effic. Motor (90.2 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT011A 7½ HP High Effic. Motor (90.2 Eff.)(575/60/3) Consult Matrix SheetsStainless Steel Heat ExchangerCan be used on all downflow or horizontal units.FIYSSHX001A 150 MBH Stainless Steel Heat Exchanger YCD/H150D,151C Low HeatFIYSSHX002A 250 MBH Stainless Steel Heat Exchanger YCD/H150D,151C High HeatYCD/H155B,175C,180B,181C,200B,210C,211C,240B,241C,250B,300B and 301C Low HeatFIYSSHX003A 350 MBH Stainless Steel Heat Exchanger YCD/H155B,175C,180B,181C,210C, 211C High HeatFIYSSHX004A 400 MBH Stainless Steel Heat Exchanger YCD/H200B,240B,241C,250B,300B,301C High Heat1 Must order when ordering through-the-base electrical or through-the-base access option (downflow only).2 Order when not ordering through-the-base electrical or through-the-base access option (downflow only).Horizontal/DownflowPackaged Gas/ElectricFactory Installed Options (FIOPS)© <strong>Trane</strong> 2007FIOP – 14 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!