Model NomenclatureVoyager R-22T C D 150 C 0 0 A A1 2 3 456 7 9 10 11 12Digit 1,2 — Unit TypeTC = Packaged Cooling, Electric HeatTF = With Factory Installed OptionsYC = Packaged Gas/ElectricYF = With Factory Installed OptionsDigit 3 — Airflow ConfigurationD = DownflowH = HorizontalDigit 4,5,6 — Nominal Gross Cooling Capacity(MBh)150 = 12½ Tons Standard Efficiency151 = 12½ Tons High Efficiency180 = 15 Tons Standard Efficiency181 = 15 Tons High Efficiency210 = 17½ Tons Standard Efficiency211 = 17½ Tons High Efficiency240 = 20 Tons Standard Efficiency241 = 20 Tons High Efficiency300 = 25 Tons Standard Efficiency301 = 25 Tons High EfficiencyDigit 7 — Major Design SequenceDigit 8 — Voltage Selection3 = 208-230/3/604 = 460/3/60W = 575/3/60K = 380/3/60Digit 9,10 — Factory Installed OptionsNote: (Applicable to Digit 1, 2 T models only)00 = No Factory-Installed Options0A = Factory-Installed Economizer0B = Oversized Motor0C = Downflow Economizer and Oversized Motor0F = <strong>Trane</strong> Communications Interface (TCI)0G = Downflow Economizer and TCI0H = TXV/Face-Split Evaporator0J = Oversized Motor and TXV Face-Split Evaporator0K = Downflow Economizer, Oversized Motor, and TXVFace-Split Evaporator0L = Downflow Economizer with TXV/Face-SplitEvaporator0M = Reheat Coil0N = Downflow Economizer and Reheat Coil0P = Oversized Motor and Reheat Coil0R = Downflow Economizer, Oversized Motor andReheat CoilDigit 9 — Heating CapacityNote: (Applicable to Digit 1, 2 Y models only)L = Low HeatH = High HeatV = Modulating Gas HeatDigit 10 — Factory Installed OptionstNote: (Applicable to Digit 1, 2 Y models only)0 = Packed Stock, No OptionsA = Downflow Economizer1B = Oversized Motor6C = Downflow Economizer and Oversized Motor1F = <strong>Trane</strong> Communications Interface (TCI)6uG = Downflow Economizer & TCI1uH = TXV/Face-Split EvaporatorrJ = Oversized Motor and TXV/Face Split EvaporatorrK = Downflow Economizer, Oversized Motor, andTXV/Face Split Evaporator1rL = Downflow Economizer with TXV Face-SplitEvaporator6rM = Reheat Coil4rN = Downflow Economizer and Reheat Coil14rP = Oversized Motor and Reheat Coil14rR = Downflow Economizer, Oversized Motor andReheat Coil14rDigit 11 — Minor Design SequenceDigit 12 — Service SequenceNote: Explanation of Model Number Notes located onthis page.Note: Most Factory Installed Options (FIOPS) availablefor Downflow Air Discharge units only. Pleaseverify with ordering system for availability.Options*Factory Installed Optionst• 2" Pleated Filters64• Black Epoxy Pre-Coated Coils6• Dehumidification Option4qr• Differential Pressure Switches• High Efficiency Motors6• Hinged Access Doors• Novar Return Air Sensore• Novar Unit Controlsy• Powered or Unpowered Convenience Outlet5• Stainless Steel Heat Exchanger with 10-yearwarranty6• Supply and/or Return Air Smoke Detector20• Thermal Expansion Valver• Through the Base Electrical Access• Through the Base Electrical with CircuitBreakerqw• Through the Base Electrical with DisconnectSwitch7qwFactory* or Field Installed Optionst• Barometric Relief• Clogged Filter/Fan Failure Switch26• Discharge Air Sensing Kit26• Economizer (Downflow)1• Electric Heaters68w• Frostat246• LonTalk ® Communications Interface (LCI)6• Oversized Motors6• Reference or Comparative36 Enthalpy• Tool-less Hail Guards6• <strong>Trane</strong> Communications Interface (TCI)6uField Installed Options• CO 2 Sensing• Digital Display Zone Sensor• Dual Thermistor Remote Zone Sensor• Economizer (Horizontal)• High Altitude Kit• High and Low Static Drive Kits• Humidity Sensor• Low Static Drive• LP Conversion Kit• Manual Outside Air Damper• Motorized Outside Air Dampers• Powered Exhaust• Quick Start Kit• ReliaTel Options Module9• Remote Potentiometer• Roof Curb (Downflow Only)• Thermostat• Ventilation Override Accessory2• Zone Sensors and Remote Zone SensorsModel Number Notes1 Some field set up required.2 Requires ReliaTel options module.3 Requires Economizer.4 All 10th digit model numbers including reheat coil (M,N,P,R)require additional factory installed options; ReliaTeloptionsmodule, Frostat, and 2" pleated filters.5 Must be ordered with Through-the-Base Electrical option orHorizontal-Side Access and either Unit Mounted Disconnect orCircuit Breaker.6 Available factory installed on downflow AND horizontal units.Verify with ordering system.7 Cannot be fused.8 Must be factory installed when using Through-the-Base Options.9 ReliaTel Options Module is required when ordering thefollowing accessories: Clogged Filter Switch, Fan Fail Switch,Discharge Air Sensing Kit, Frostat, Ventilation Override, SmokeDetector, Dehumidification and Modulating Gas Heat Furnace.0 Option cannot be ordered in conjunction with field installedeconomizer on downflow units. Must be factory installed. Thereturn air smoke detector may not fit up or work properly on theVoyager units when used in conjunction with 3rd party accessories(such as bolt on heat wheels, economizers, and powerexhaust). Do not order the return air smoke detectors whenusing this type of accessory.q Unit mounted disconnect and circuit breakers are mutuallyexclusive of each other.w Through-the-base electrical option or Horizontal-Side Accessmust be ordered with either unit mounted disconnect or circuitbreaker. When adding heat, must order <strong>Trane</strong> Electric Heat.e This option consists of the Novar return air sensor (Novar#WTS-10) that is wired and shipped in the return air section ofthe unit. The sensor ships with approximately 15' of extra wirefor dropping down the return air duct (downflow only).r Available on high efficiency, downflow units only.t All Factory Installed Options are Built-to-Order. Check orderservices for estimated production cycle.y The Novar control option includes the following factory installedand wired devices: Novar ETM-2024 or Novar 3051 rooftopcontroller, fan proving switch, clogged filter or unit shutdownswitch, Cool 1, Cool 2, Heat switch and discharge air sensor(Novar 2024 is downflow only). Note:Option cannot be orderedin conjunction with FIOPS Smoke Detector option.u TCI is for use with non-VariTrac systems and VariTrac systems.Note: *Most Factory Installed Options (FIOPS) available for DownflowAir Discharge units only. Please verify with orderingsystem for availability.© <strong>Trane</strong> 2007PC – 47 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!