12.07.2015 Views

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

2008 Trane Product Catalog - Blue Phoenix Mechanical

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Model NomenclaturePrecedent PackagedHeat PumpsR-410AW S C 036 E 3 R B A ** C 0 0 0 A 1 0 0 0 1 A 11 2 3 4,5,6 7 8 9 10 11 12,13 14 15 16 17 18 19 20 21 22 23 24 25DIGIT 1 - Unit FunctionW = Packaged Heat Pump1DIGIT 2 - EfficiencyS = Standard Efficiency (13 SEER R-410A)DIGIT 3 -AirflowC = ConvertibleDIGITS 4,5,6 - Nominal Gross CoolingCapacity (MBh)036 = 3 Ton046 = 4 Ton060 = 5 TonDIGIT 7 - Major Design SequenceE = R-410A RefrigerantDIGIT 8 - Unit Voltage1 = 208-230/1/603 = 208-230/3/604 = 460/3/60W = 575/3/60DIGIT 9 - Unit ControlsR = ReliaTelMicroprocessorDIGIT 10 - Heating CapacityNote: (Applicable to Digit 1, W models only)0 = No Electric HeatA = 5 kW (1 phase)1B = 6 kW (3 phase)C = 9 kW (3 phase)3D = 10 kW (1 phase)1E = 12 kW (3 phase)F = 14 kW (1 phase)1G = 18 kW (1&3phase)J = 23 kW (3 phase)DIGIT 11 - Minor Design SequenceA = First SequenceDIGITS 12, 13 - Service Sequence** = Factory AssignedDIGIT 14 - Fresh Air Selection0 = No Fresh AirA = Manual Outside Air Damper 0-50%5B = Motorized Outside Air Damper 0-50%C = Economizer, Dry Bulb 0-100%without Barometric Relief8D = Economizer, Dry Bulb 0-100%with Barometric Relief8E = Economizer, Reference Enthalpy0-100% without Barometric Relief48F = Economizer, Reference Enthalpy0-100% with Barometric Relief48G = Economizer, Comparative Enthalpy0-100% without Barometric Relief48H = Economizer, Comparative Enthalpy0-100% with Barometric Relief48DIGIT 15 - Supply Fan/Drive Type/Motor0 = Standard Drive7DIGIT 16 - Hinged Service Access/Filters0 = Standard Panels/Standard FiltersA = Hinged Access Panels/Standard FiltersB = Standard Panels/2” Pleated FiltersC = Hinged Access Panels/2” Pleated FiltersDIGIT 17 - Condenser Coil Protection0 = Standard Coil1 = Standard Coil with Hail Guard2 = Epoxy Pre-Coated Condenser Coil3 = Epoxy Pre-Coated Condenser Coil with Hail Guard4 = CompleteCoat Condenser Coil5 = CompleteCoat Condenser Coil with Hail GuardDIGIT 18 - Through the Base ProvisionsNote: (Applicable to Digit 1, W models only)0 = No Through the Base ProvisionsA = Through the Base Electric9DIGIT 19 - Disconnect/Circuit Breaker/Phase Monitor (3 phase only)0 = No Disconnect/No Circuit Breaker/No PhaseMonitor1 = Unit Mounted Non-Fused Disconnect92 = Unit Mounted Circuit Breaker93 = Phase Monitor4 = Phase Monitor & Non-Fused Disconnect Switch5 = Phase Monitor & Circuit BreakerDIGIT 20 - Convenience Outlet0 = No Convenience OutletA = Unpowered Convenience OutletB = Powered Convenience Outlet (3 phase only)0DIGIT 21 - Communications Options40 = No Communications Interface1 = <strong>Trane</strong> Communications Interface2 = LonTalk ® Communications InterfaceDIGIT 22 - Refrigeration System Option0 = Standard Refrigeration CoilqDIGIT 23 - Refrigeration Controls0 = No Refrigeration Control61 = Frostatw2 = Crankcase Heater23 = Frostatw and Crankcase HeaterDIGIT 24 - Smoke Detector4u0 = No Smoke DetectorA = Return Air Smoke DetectorerB = Supply Air Smoke DetectorC = Supply and Return Air Smoke DetectorserDIGIT 25 - Monitoring Controls50 = No Monitoring Controlt1 = Clogged Filter Switcht2 = Fan Failure Switcht3 = Discharge Air Sensing Tubet4 = Clogged Filter Switch and Fan Fail Switcht5 = Clogged Filter Switch and Discharge Air SensingTubet6 = Fan Fail Switch and Discharge Air Sensing Tubet7 = Clogged Filter and Fan Fail Switchesand Discharge Air Sensing Tubet8 = Novar Return Air SensoryExplanation of Model Number Notes1-17 follow. Unless otherwise noted,feature available for all W models,tonnages and phases.1 Available for R-410A units only.2 Standard on 4 ton , 3 phase Heat Pumps and 5 ton HeatPumps.3 Available for R-22 units only.4 Not available with electromechanical controls.5 Manual outside air damper will ship factory supplied withinthe unit, but must be field installed.6 High pressure control is standard on all units.7 Multispeed direct drive standard on 1 phase. Belt drivestandard on 3 phase.8 Economizer with Barometric Relief is for downflowconfigured units only. Order Economizer without BarometricRelief for horizontal configuration. Barometric Relieffor horizontal configured units must be ordered as fieldinstalled accessory.9 Through the base electric required when ordering disconnect/circuitbreaker options.0 Requires use of Disconnect or Circuit Breaker.q Standard metering devices are TXVs.w Frostat cannot be field installed in electro-mechanical units.e The return air smoke detector may not fit up or workproperly on the Precedent units when used in conjunctionwith 3rd party accessories such as bolt on heat wheels,economizers and power exhaust. Do not order the returnair smoke detectors when using this type of accessory.r Return air smoke detector cannot be ordered with NovarControls.t These options are standard when ordering Novar Controls.y This option is used when ordering Novar Controls.u Not available with high temperature stat accessory.Example:Model number WSC036E3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power supply,ReliaTel controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard belt drive motor, standard access panels/filters, standardcondenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard refrigeration coil, highpressure control, return air smoke detector, and clogged filter switch.© <strong>Trane</strong> 2007PH – 36 Effective date: January 1, <strong>2008</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!